Knowledge centre · Industrial chemicals

Urea as the reagent for NOx reduction in boilers, furnaces and kilns

How stationary plants use urea for NOx control by SNCR and SCR, why it is chosen over ammonia, and what affects performance, slip and urea quality.

Written by the Nuroil trade desk, Sharjah

Illustration of Nuroil technical grade urea at a chemical plant
On this page · 6 sections
  1. 01Why urea instead of ammonia
  2. 02Urea in SNCR
  3. 03Urea in SCR
  4. 04How the urea is stored and dosed
  5. 05Urea and water quality
  6. 06Specifying urea for NOx control

Power stations, industrial boilers, cement kilns, waste incinerators and process furnaces all produce nitrogen oxides (NOx). Two common ways of removing them use a nitrogen-based reagent: selective non-catalytic reduction (SNCR), where the reagent is injected into the hot furnace gas, and selective catalytic reduction (SCR), where reaction takes place over a catalyst at lower temperature. Urea is one of the main reagents for both. This article explains how it is used and what plant operators should consider when buying it.

Why urea instead of ammonia

Ammonia, either anhydrous or as an aqueous solution, is the other main reagent. Anhydrous ammonia is usually the cheapest per unit of reducing power, but it is a toxic, pressurised gas, and its storage triggers strict safety rules in many places. Aqueous ammonia is less concentrated but carries similar concerns. Urea is a stable, non-volatile solid that is shipped and stored without pressure, which is why many plants near populated areas choose it.

The main trade-offs are reagent cost and some chemistry differences. Urea solution must be kept warm in storage, and urea-based SNCR tends to form more nitrous oxide (N₂O) as a by-product than ammonia-based systems.

Urea in SNCR

In SNCR, urea solution is sprayed as droplets into the furnace where the gas temperature is in the right window. For urea this is commonly given as roughly 900–1,150 °C. Below the window the reaction is too slow and unreacted ammonia escapes. Above about 1,090 °C, ammonia begins to oxidise and can produce NO instead of removing it. Because the furnace temperature profile shifts with load, systems use several injection levels and switch between them.

Key points from the US EPA's cost manual on SNCR:

  • Theoretically half a mole of urea removes one mole of NO, but in practice more reagent is needed. The normalised stoichiometric ratio for urea in boilers usually falls between 0.5 and 2.0, with reagent utilisation around 25–50%.
  • NOx reductions on utility boilers are mostly 20–35%; cement kiln installations have reported roughly 35–58%.
  • Ammonia slip, the unreacted reagent leaving the stack, is generally held to 2–10 ppm. Excess slip forms ammonium sulphate and bisulphate salts with sulphur-bearing fuels, fouling air heaters and ducts.
  • Up to around 30% of the NOx removed can be converted to N₂O with urea, depending on temperature and dose.

Urea in SCR

SCR systems need ammonia at the catalyst. Plants that prefer not to store ammonia can generate it on site from urea, using hydrolysis or decomposition units that convert urea solution into a gas mixture of ammonia, carbon dioxide and water vapour. This keeps the benefits of urea storage while feeding the catalyst the ammonia it needs. The conversion needs heat, which adds to operating cost, and ammonia is still present in the process lines.

How the urea is stored and dosed

StepTypical practice
DeliveryAs solid urea, or as concentrated solution (commonly 50%, sometimes higher)
Storage50% solution in heated, circulated tanks, since it begins to crystallise below about 18 °C
DilutionDiluted with filtered plant water, often to around 5–10%, before injection
InjectionThrough atomising lances at several levels, controlled against outlet NOx and load

Plants receiving solid urea need a dissolving system. The EPA notes this is generally economic mainly for remote sites; elsewhere, solution delivered by road or rail is common.

SNCR performance is set by temperature, mixing and dose. Urea quality decides whether the injectors stay clean.

Urea and water quality

Nozzles and lances are prone to plugging. Solution is filtered before the injectors, and EPA guidance describes dilution water filtered to below 50 mg/L of suspended solids with low dissolved solids. Hard water can deposit scale. For the urea itself, low insoluble matter and a known biuret content help keep strainers and nozzles clear. Formaldehyde-based conditioners are usually not a problem for combustion processes, but they should be declared.

Specifying urea for NOx control

Tell the supplier whether the urea is for SNCR, for an SCR urea-to-ammonia unit, or for DEF-quality use, as limits differ. Specify form, nitrogen, biuret, insolubles and moisture, plus packing suited to your dissolving system. Nuroil supplies technical-grade urea with a certificate of analysis on every delivery. Use our quote request form to share your requirements.