Technical document

· PDF

Tell us who you are and the document downloads straight away. We use these details only to follow up on your requirement.

Samples & documents

What can we send you?

Tick what you need
Request a quote
Guide3 min read6 sections

Knowledge centre · Waterproofing & construction

Storing and shipping solvent-based bitumen primer: flammability rules

Flash point, dangerous goods classification, warehouse storage and site handling for solvent-based bitumen primer in pails and drums.

Written by the Nuroil trade desk, Sharjah

NURPRIME SB solvent-based bitumen primer
On this page · 6 sections
  1. 01Flash point and why it varies
  2. 02Dangerous goods classification
  3. 03Warehouse storage
  4. 04On site
  5. 05Handling spills
  6. 06Documents to request

Solvent-based bitumen primer is a flammable liquid. That single fact shapes how it is packed, shipped, stored in a warehouse and handled on site. Getting it right keeps people safe and avoids delays at ports and with carriers. This guide covers the main points; the product's safety data sheet is always the controlling document.

Flash point and why it varies

Flash point is the lowest temperature at which a liquid gives off enough vapour to ignite. Solvent-based primers use different solvent blends, so flash points differ widely:

  • several primers made in the Gulf region list flash points around 38 °C;
  • some European primers list about 23 to 40 °C;
  • a North American primer using faster solvents lists a closed-cup flash point below -18 °C.

In a hot climate, a flash point around 38 °C offers little margin: summer air and container temperatures can exceed it. All of these products should be treated as able to produce flammable vapour in normal use.

Dangerous goods classification

For transport, flammable liquids fall in Class 3. The packing group depends mainly on flash point and boiling point: products with higher flash points are often Packing Group III, while low flash point products may be Packing Group II. As an example, one primer data sheet lists Class 3, UN 1999 (tars, liquid), Packing Group III. Other primers may be shipped under a different UN entry depending on their composition.

ItemWhere to find itWhy it matters
UN number and proper shipping nameSDS section 14Booking, labelling and documents
Class and packing groupSDS section 14Packaging, segregation and carrier acceptance
Flash pointSDS section 9Storage design and site controls
Packaging marksOn the pail or drumUN-approved packaging for dangerous goods

Shipping lines need a dangerous goods declaration and correctly marked and labelled packages. Container bookings for Class 3 cargo can take longer to confirm, so build that into the schedule.

Warehouse storage

Guidance on storing flammable liquids in containers, such as the UK HSE publication HSG51, sets out general principles that also suit primer stocks:

  • store in a dedicated, well-ventilated area or cabinet, preferably outdoors or in a separate building;
  • keep away from ignition sources, oxidisers and occupied areas;
  • provide spill containment so leaks cannot reach drains;
  • keep quantities in work areas to the minimum needed;
  • provide suitable fire extinguishers and clear signage.

Product data sheets add their own conditions: a covered, dry and shaded store away from direct sunlight, UV and heat. Heat raises vapour pressure inside closed containers and shortens shelf life, which is typically up to 12 months.

On site

  1. Keep the main stock in a shaded, ventilated, fenced area away from hot work.
  2. Bring only the day's requirement to the work face, in closed containers.
  3. Do not store primer on roofs where torches and gas cylinders are in use.
  4. Never warm primer or speed its drying with a flame.
  5. Collect used rags, rollers and brushes in closed metal bins.
  6. Return part-used pails to the store with lids sealed.
Treat solvent-based primer as a flammable liquid from the moment it is packed until the last coat has fully dried.

Handling spills

Remove ignition sources, ventilate the area, and contain the spill with sand or a suitable absorbent. Prevent it from entering drains. Dispose of absorbed material according to local regulations and the SDS.

Documents to request

Ask for the safety data sheet in the language required at destination, the technical data sheet, the certificate of analysis and the dangerous goods details for booking. If your local rules restrict flash point or VOC content, state the limit in your enquiry. Nuroil supplies solvent-based bitumen primers in pails and drums with CoA on every delivery and MSDS on request; contact us through contact us or request a quote.

PRODUCTS IN THIS GUIDE
KEEP READING

More from the knowledge centre.

STILL HAVE A QUESTION?

Ask the people who trade it every day.

Our trade managers answer technical and commercial questions about grades, specifications, packing and shipping.

LET’S TALK ABOUT YOUR REQUIREMENTS

Your next shipment starts here.

Request a quote