Knowledge centre · Caustic soda & soda ash

Soda ash specification parameters explained

What each line on a soda ash specification means: Na2CO3, Na2O, chloride, iron, sulphate, insolubles, moisture, bulk density and particle size.

Written by the Nuroil trade desk, Sharjah

Pencil sketch of soda ash production
On this page · 5 sections
  1. 01The main chemical parameters
  2. 02Physical parameters
  3. 03Typical values at a glance
  4. 04Sampling and test methods
  5. 05Building your own specification

A soda ash certificate of analysis usually lists eight to twelve parameters. Most good-quality product meets similar chemical limits, so the useful skill is knowing which values matter for your process and how to read them. This guide explains each common parameter and gives typical values from published producer data sheets.

The main chemical parameters

01

Sodium carbonate (Na2CO3)

This is the assay, normally determined by titration with standard acid and reported on a dry basis. Commercial technical grades are typically 99.2% or higher, and many producers guarantee 99.5% or more.
02

Sodium oxide (Na2O) equivalent

Some specifications express alkali content as Na2O. Pure sodium carbonate contains about 58.5% Na2O, so a 99% product corresponds to about 57.9% Na2O. Water-treatment purchasing standards use this pair of thresholds.
03

Sodium chloride (NaCl)

Chloride comes from the raw materials and process. It matters in glass, in some chemical syntheses and wherever chloride causes corrosion. Published limits range from a few hundredths of a percent up to about 0.25%.
04

Iron (Fe or Fe2O3)

Iron is reported in ppm or as a percentage of Fe2O3. It is critical in clear glass and in some detergent and chemical uses because it causes colour. Good grades are typically below 0.004% Fe2O3 (40 ppm).
05

Sodium sulphate (Na2SO4)

Typically a few hundredths of a percent. It is watched in glass batch chemistry and some chemical processes.
06

Water-insoluble matter

Grit and other insolubles left after dissolving. These matter in solution systems, where they settle in tanks and block filters and nozzles. Typical limits are a few hundredths of a percent.
07

Loss on heating or moisture

Soda ash takes up moisture and carbon dioxide from the air. This adds weight and lowers the measured assay, though the total alkali present does not change. Limits of about 0.5% are common.

Physical parameters

01

Bulk density

This separates the grades. Light soda ash is typically about 0.5–0.65 kg/L, and dense soda ash about 0.95–1.1 kg/L. Check whether a figure is loose (poured) or tapped, because tapped values are higher.
02

Particle size distribution

Reported as cumulative percentages retained on or passing standard sieves. For dense ash, producers commonly limit oversize (for example, a few percent retained at around 600 µm), state a minimum fraction retained at about 150 µm, and limit fines passing about 75 µm to a few percent. Glassmakers and dry-feed users care most about this parameter.

Typical values at a glance

ParameterTypical specification (dense grade)Who watches it most
Na2CO3, dry basis99.2–99.6% minAll users
NaCl0.04–0.25% max, depending on sourceGlass, chemicals
Fe2O3about 0.004% maxClear glass, detergents
Na2SO4about 0.02–0.05% maxGlass
Water insolublesabout 0.02–0.05% maxSolution users, water treatment
Loss on heatingabout 0.5% maxAll users
Bulk density0.95–1.1 kg/L (light: 0.5–0.65)Storage, dosing equipment
Fines below about 75 µma few percent maxGlass, dry feeders

These are indicative ranges drawn from producer data. The values that apply to a contract are those agreed in the specification.

Sampling and test methods

Results only mean something if the sample represents the lot. Vibration during transport can separate coarse and fine grains in dense ash, so samples taken from the top of a bulk load can mislead. Take samples at several depths, or from a moving stream during loading, and mix them. Rough handling and pneumatic conveying can also break grains and raise the moisture pick-up.

Analysis normally follows recognised methods such as ASTM E359 or the methods referenced in water-treatment standards. Agree the method in the contract if a parameter is critical, because different sieve sets or drying temperatures give different numbers.

Building your own specification

Start from your process. Include only the parameters that affect it, with sensible limits, plus the grade and packing. Ask for a certificate of analysis for each lot. For a new supply, ask for a sample or a set of past analyses to judge consistency. Third-party inspection at loading is useful for large or critical shipments. Nuroil provides a CoA with every soda ash delivery and can arrange independent inspection on request.