Technical document

· PDF

Tell us who you are and the document downloads straight away. We use these details only to follow up on your requirement.

Samples & documents

What can we send you?

Tick what you need
Request a quote
Guide3 min read8 sections

Knowledge centre · Caustic soda & soda ash

Caustic soda specifications and what each parameter means

A reference to the parameters on a caustic soda specification: NaOH content, sodium carbonate, sodium chloride, iron and other trace impurities.

Written by the Nuroil trade desk, Sharjah

Pencil sketch of caustic soda flakes and pearls
On this page · 8 sections
  1. 01NaOH content (assay)
  2. 02Sodium carbonate (Na₂CO₃)
  3. 03Sodium chloride (NaCl)
  4. 04Iron (Fe or Fe₂O₃)
  5. 05Other parameters you may see
  6. 06Typical figures at a glance
  7. 07Standards and certified grades
  8. 08Writing the specification into your enquiry

A caustic soda specification or certificate of analysis usually lists a handful of parameters: sodium hydroxide content, sodium carbonate, sodium chloride and iron, sometimes with chlorate, sulphate and heavy metals. Each one tells you something about how the product was made and handled, and whether it suits your process. This guide explains them.

NaOH content (assay)

The assay is the percentage by weight of sodium hydroxide. For solid flakes and pearls a typical minimum is 98%. For liquid caustic the standard commercial strength is about 50%, usually specified as a range such as 49.5 to 51.5%.

The assay determines how much product you need. If a process was designed around 50% lye and you switch to flakes, you dose roughly half the weight. Some laboratories report "total alkalinity", which includes carbonate as well as hydroxide; check which basis the certificate uses.

Sodium carbonate (Na₂CO₃)

Carbonate forms when caustic soda reacts with carbon dioxide from the air. Some is present from manufacture, and more can form in storage if bags are left open or tanks are agitated with air. Carbonate is alkali that is not available as hydroxide, and in some processes it can form scale or unwanted precipitates. Data sheets for flake grades commonly set a maximum of around 0.2%, while membrane-grade 50% liquor is often limited to about 0.1%.

Because carbonate rises with exposure to air, samples for carbonate testing should be taken first and handled quickly.

Sodium chloride (NaCl)

Chloride comes from the salt brine used to make caustic soda. Its level depends mainly on the electrolysis technology. Membrane-cell caustic is low in chloride, with typical producer limits near 100 ppm in 50% solution. Caustic from older cell technologies can contain much more unless it is purified. Chloride matters for users concerned about stress corrosion of stainless steel, and in applications such as rayon, pharmaceuticals and electronics.

Iron (Fe or Fe₂O₃)

Iron mostly enters from contact with steel equipment during production, storage and transport. Liquid caustic stored or heated in unlined steel picks up iron faster at higher temperatures. Limits are low: membrane 50% liquor is often specified at around 3 ppm Fe maximum, and flake grades at around 15 mg/kg expressed as Fe₂O₃. Note whether iron is reported as Fe or as Fe₂O₃, since the numbers are not directly comparable. Iron can discolour soaps, textiles and paper products.

Other parameters you may see

  • Sodium chlorate (NaClO₃): an oxidising by-product of electrolysis, typically limited to a few tens of ppm in membrane liquor.
  • Sodium sulphate (Na₂SO₄): from brine impurities, also typically a few tens of ppm.
  • Nickel, copper and mercury: trace metals of concern in food, pharmaceutical and drinking-water uses.
  • Appearance: solids should be white; liquid should be clear to slightly hazy and colourless.

Typical figures at a glance

ParameterFlakes or pearls (typical limit)Membrane-grade 50% lye (typical limit)
NaOH98% min49.5 to 51.5%
Na₂CO₃About 0.2% maxAbout 0.1% max
NaClAbout 0.02% maxAbout 100 ppm max
IronAbout 15 mg/kg as Fe₂O₃ maxAbout 3 ppm as Fe max
NaClO₃Not always specifiedAbout 40 ppm max

These figures are representative of published producer data sheets, not a standard. Limits vary between producers and grades, so always work from the specification for the specific product offered.

Standards and certified grades

For drinking-water treatment, buyers commonly specify EN 896 in Europe, or AWWA B501 together with NSF/ANSI 60 certification elsewhere. Food and pharmaceutical users may require pharmacopoeia or food-additive grades. A technical grade is fine for many industrial uses, but a certified grade cannot be substituted by a technical one simply because the assay looks similar.

Read a caustic soda certificate as a record of the product's history: chloride reflects the cell process, iron reflects steel contact, and carbonate reflects exposure to air.

Writing the specification into your enquiry

List each parameter with a maximum or minimum, the test basis (for example iron as Fe or Fe₂O₃) and any standard the product must meet. Ask for a certificate of analysis per lot and agree whether results apply at loading or on arrival. Nuroil provides a certificate of analysis with every delivery, with third-party inspection available on request; send your specification via request a quote.

PRODUCTS IN THIS GUIDE
KEEP READING

More from the Knowledge Centre.

STILL HAVE A QUESTION?

Ask the people who trade it every day.

Our trade managers answer technical and commercial questions about grades, specifications, packing and shipping.

LET’S TALK ABOUT YOUR REQUIREMENTS

Your next shipment starts here.

Request a quote