Prilled sulphur quality: size, moisture, friability and dust

A reference to the physical quality parameters of prilled sulphur, how they are judged under SUDIC criteria and why each one matters in handling.

Written by the Nuroil trade desk, Sharjah

Pencil sketch of prilled sulphur
On this page · 6 sections
  1. 01The four SUDIC quality factors
  2. 02Parameters and why they matter
  3. 03Reference figures from formed sulphur data
  4. 04Ageing changes friability
  5. 05Reading a prilled sulphur data sheet
  6. 06Putting it into your specification

Chemical purity tells you what prilled sulphur is made of. Physical quality tells you how it will behave when it is loaded, shipped, stored and fed into a plant. For formed sulphur, the physical side has its own framework, developed by the Sulphur Development Institute of Canada (SUDIC) in the late 1970s and still widely used to describe premium and standard products.

The four SUDIC quality factors

SUDIC judged formed sulphur on four physical properties:

  1. Shape. Rounded particles flow and stack predictably and break less than angular ones.
  2. Particle size distribution. Formed sulphur is generally expected to fall mostly between about 2 and 6 mm.
  3. Moisture. Lower moisture means less acid, less corrosion and less weight paid for water.
  4. Friability. How easily the particles break into dust under handling stress.

Products meeting all four at the tightest levels are classed as premium; others as standard. Granules and pastilles from modern plants generally meet the premium criteria. Wet prills usually fall short on moisture and are treated as standard quality, though their other properties can be good.

Parameters and why they matter

ParameterWhat it tells youWhy it matters
Size rangeShare of material within the target band, often 2 to 6 mmUniform size flows and blends predictably
FinesShare below the lower size limitFines are the main source of dust and fire risk
MoistureWater content by weightAffects acid formation, corrosion, melting and price paid per tonne of sulphur
FriabilityFines created under a set impact or abrasion testPredicts dust generated by conveying, loading and discharge
Bulk densityMass per volume, loose and compactedDetermines storage, hold and container space
Angle of reposeSlope a free pile formsAffects stockpile footprint and hopper design

Reference figures from formed sulphur data

Published product data for modern formed sulphur illustrate what good physical quality looks like. Granulated sulphur, for example, has been reported with moisture below 0.5%, dust below 0.5%, friability below 2% under a standard stress test and loose bulk density above about 1,040 kg per cubic metre. Belt-formed pastilles report similar dust and friability with even lower moisture. Prills vary more with the process used, so ask for the producer's own figures rather than assuming these values.

Ageing changes friability

Freshly formed sulphur contains a share of metastable polymeric sulphur and other crystal forms that convert slowly to the stable form over days and weeks. As this happens, particles can become more brittle. Research on different forms has shown that friability changes with age, and that it can differ depending on whether the liquid sulphur was degassed before forming. A product that tested well at the plant may generate more dust after long storage or a long voyage.

Reading a prilled sulphur data sheet

  • Check whether moisture is quoted as typical or maximum, and at what point (production, loading or discharge).
  • Check the size band and how much material sits below it.
  • Ask which friability test was used, since different methods give different numbers.
  • Look for a statement of forming process; water-prilled and air-prilled products differ.
Two prilled sulphurs with identical purity can generate very different amounts of dust. Physical quality deserves its own place in the specification.

Where physical quality is critical, ask for size and fines to be checked by an independent inspector at loading, and repeat the check at discharge to see how much breakdown occurred on the way.

Putting it into your specification

Alongside purity, ash, carbon and acidity, state the size range, maximum fines, maximum moisture and, if dust is a concern, a friability limit with the test method. Nuroil provides a CoA with every delivery and third-party inspection on request; request a quote with your requirements.