Technical document

· PDF

Tell us who you are and the document downloads straight away. We use these details only to follow up on your requirement.

Samples & documents

What can we send you?

Tick what you need
Request a quote
Guide3 min read7 sections

Knowledge centre · Waterproofing & construction

HPMC viscosity grades for construction explained

What HPMC viscosity grades mean, why Brookfield and NDJ readings differ, and how grade choice maps to plasters, renders, skim coats and tile adhesives.

Written by the Nuroil trade desk, Sharjah

Pencil sketch of a roof being waterproofed with bitumen membrane
On this page · 7 sections
  1. 01How viscosity is measured
  2. 02Brookfield and NDJ numbers are not interchangeable
  3. 03Tolerance on nominal viscosity
  4. 04Typical grade choices by product
  5. 05Viscosity and water retention
  6. 06Beyond viscosity
  7. 07Specifying a grade

HPMC for construction is sold mainly by viscosity grade, often shown as a number such as 40,000, 75,000 or 100,000 in a product name. The number looks precise but means little unless you know how it was measured. This guide explains how viscosity grades are defined, why readings from different instruments disagree, and how grade relates to the products HPMC goes into.

How viscosity is measured

Viscosity is measured on a dilute solution of HPMC in water, most often 2% by mass at 20 °C, using a rotational viscometer. The method details matter:

  • Concentration: 2% is common, but some data sheets use 1% for very high grades. Viscosity rises steeply with concentration.
  • Temperature: HPMC solutions thin as they warm, until they reach the gel temperature, where they thicken suddenly.
  • Instrument: Brookfield and NDJ rotational viscometers are both widely used, with different spindles and speeds.
  • Dry basis: some methods correct for the sample's moisture content.

Brookfield and NDJ numbers are not interchangeable

For the same material, NDJ readings in supplier data are often around two to three times the Brookfield reading, and the ratio varies from grade to grade. A grade sold as "200,000" on one scale may be close to another seller's "75,000" on the other. There is no reliable fixed conversion factor, so always compare grades on the same method, or test samples side by side in your own laboratory.

Tolerance on nominal viscosity

A nominal grade covers a range. Pharmacopoeial monographs for hypromellose, which define the purest grades, allow 75% to 140% of the labelled value for grades of 600 mPa·s and above. Construction-grade data sheets usually state their own range around the nominal figure. A wide tolerance means two lots of the same grade can behave noticeably differently, so it is worth agreeing a tighter range for critical products.

Typical grade choices by product

ProductGeneral directionReason
Self-levelling compoundsLow viscosityWater retention and stability without stopping flow
Gypsum machine plasterLow to mediumPumpability and easy finishing; very high grades can be tacky
Cement render and masonry mortarMediumBalance of water retention and workability
Skim coat and wall puttyMedium to highThin layers lose water quickly
Tile adhesiveHighOpen time and slip resistance for wall tiles

These are tendencies, not rules. The final choice depends on the whole formulation, and many producers blend two grades to reach a target rheology.

Viscosity and water retention

Higher viscosity generally gives more water retention at the same dosage, because the thickened pore solution and the polymer film slow water movement. Research on cement mortar has shown water retention correlating closely with mortar plastic viscosity. Supplier literature suggests the gain becomes small at the very highest grades, so paying for extreme viscosity is not always worthwhile.

Beyond viscosity

Two HPMCs with the same viscosity can still perform differently because of:

  • Substitution: the methoxyl and hydroxypropyl contents influence gel temperature, solubility and surface activity. Pharmacopoeias classify hypromellose into substitution types such as 2910, 2906 and 2208 by these contents.
  • Particle size: finer powders dissolve faster and give earlier thickening.
  • Surface treatment: delayed-dissolution grades disperse without lumps and dissolve as pH rises.
  • Modification: some construction grades are blended with other additives for slip resistance or workability.

Specifying a grade

When you enquire, give the nominal viscosity together with the instrument, spindle, speed, concentration and temperature, plus the acceptable range. Add the end use, particle size, any surface treatment requirement and the quantity. Ask for a sample and a CoA showing the measured viscosity for the lot. Nuroil supplies HPMC on request to construction chemical manufacturers; send your requirements via the quote form.

PRODUCTS IN THIS GUIDE
KEEP READING

More from the Knowledge Centre.

STILL HAVE A QUESTION?

Ask the people who trade it every day.

Our trade managers answer technical and commercial questions about grades, specifications, packing and shipping.

LET’S TALK ABOUT YOUR REQUIREMENTS

Your next shipment starts here.

Request a quote