Data sheets for liquid-applied elastomeric SBS bitumen coatings use a mix of descriptive claims and measured values. The measured values are what allow a buyer to compare products and check deliveries. This guide explains the usual parameters, the relevant standards and how to interpret them.
Which standards apply
There is no single worldwide standard for these coatings, so data sheets cite different references:
- EN 15814 sets requirements for polymer modified bituminous thick coatings used to waterproof parts of structures in contact with the ground, for single- and two-component products. It does not cover roof waterproofing.
- EN 15812 is the companion test for crack bridging ability of these coatings, and further companion standards cover low-temperature flexibility, resistance to compression, rain resistance and water resistance.
- ASTM D1227 covers emulsified asphalt used as a protective roof coating and includes tests such as residue, flexibility, water resistance and heat behaviour; it is a useful reference for roof uses of emulsion-based products.
Liquid properties
These describe the product in the drum and are useful for checking a delivery.
| Parameter | What it tells you |
|---|---|
| Appearance and colour | Homogeneous liquid, usually brown when wet and black when dry for emulsions |
| Density / specific gravity | Converts litres to kilograms; quick identity check |
| Solids content | Share of the product that remains as film; sets wet-to-dry thickness ratio |
| Viscosity or consistency | Whether it suits brush, roller or spray, and sag on walls |
| Base | Water-based or solvent-based; affects drying, odour and fire risk |
| Shelf life and storage temperature | How long it stays usable and how to store it |
Cured film properties
| Parameter | Typical test basis | Why it matters |
|---|---|---|
| Elongation at break | Tensile test on free film | How far the film stretches before tearing |
| Crack bridging | EN 15812 | Width of crack the film spans without failing |
| Low-temperature flexibility | Mandrel bend at set temperature | Resistance to cracking in cold |
| Heat resistance / flow | Film held at elevated temperature | Resistance to sagging on walls and in sun |
| Water resistance / watertightness | Immersion or water pressure test | Ability to hold back water once cured |
| Rain resistance | Exposure of fresh film to water | How soon after application it survives rain |
| Adhesion to concrete | Pull-off test | Bond to the substrate |
Interpreting the numbers
Solids content
Elongation
Drying times
Dry film thickness as part of the specification
Industry guidance on liquid membranes recommends that designers specify the dry film thickness rather than only the consumption rate, and that installers verify wet film thickness during application. The data sheet should give the consumption needed to reach the stated DFT on a smooth surface.
What to include in an enquiry
State the use (below ground, wet area, roof under cover), the standard you need the product declared against, and the target dry film thickness. Ask for the data sheet with the values above, the safety data sheet and a certificate of analysis for each batch, showing at least density and solids. Nuroil supplies elastomeric SBS bitumen coating with these documents and third-party inspection on request through request a quote.