Technical document

· PDF

Tell us who you are and the document downloads straight away. We use these details only to follow up on your requirement.

Samples & documents

What can we send you?

Tick what you need
Request a quote
Guide3 min read6 sections

Knowledge centre · Waterproofing & construction

Elastomeric SBS bitumen coating specifications and test methods

The parameters on an elastomeric SBS bitumen coating data sheet, how each is tested and what values matter for foundations, wet areas and roofs.

Written by the Nuroil trade desk, Sharjah

NURPROOF elastomeric SBS coating
On this page · 6 sections
  1. 01Which standards apply
  2. 02Liquid properties
  3. 03Cured film properties
  4. 04Interpreting the numbers
  5. 05Dry film thickness as part of the specification
  6. 06What to include in an enquiry

Data sheets for liquid-applied elastomeric SBS bitumen coatings use a mix of descriptive claims and measured values. The measured values are what allow a buyer to compare products and check deliveries. This guide explains the usual parameters, the relevant standards and how to interpret them.

Which standards apply

There is no single worldwide standard for these coatings, so data sheets cite different references:

  • EN 15814 sets requirements for polymer modified bituminous thick coatings used to waterproof parts of structures in contact with the ground, for single- and two-component products. It does not cover roof waterproofing.
  • EN 15812 is the companion test for crack bridging ability of these coatings, and further companion standards cover low-temperature flexibility, resistance to compression, rain resistance and water resistance.
  • ASTM D1227 covers emulsified asphalt used as a protective roof coating and includes tests such as residue, flexibility, water resistance and heat behaviour; it is a useful reference for roof uses of emulsion-based products.

Liquid properties

These describe the product in the drum and are useful for checking a delivery.

ParameterWhat it tells you
Appearance and colourHomogeneous liquid, usually brown when wet and black when dry for emulsions
Density / specific gravityConverts litres to kilograms; quick identity check
Solids contentShare of the product that remains as film; sets wet-to-dry thickness ratio
Viscosity or consistencyWhether it suits brush, roller or spray, and sag on walls
BaseWater-based or solvent-based; affects drying, odour and fire risk
Shelf life and storage temperatureHow long it stays usable and how to store it

Cured film properties

ParameterTypical test basisWhy it matters
Elongation at breakTensile test on free filmHow far the film stretches before tearing
Crack bridgingEN 15812Width of crack the film spans without failing
Low-temperature flexibilityMandrel bend at set temperatureResistance to cracking in cold
Heat resistance / flowFilm held at elevated temperatureResistance to sagging on walls and in sun
Water resistance / watertightnessImmersion or water pressure testAbility to hold back water once cured
Rain resistanceExposure of fresh film to waterHow soon after application it survives rain
Adhesion to concretePull-off testBond to the substrate

Interpreting the numbers

01

Solids content

is the most useful single figure for cost comparisons. Two products at the same price per litre with different solids will deliver different dry films per litre. Calculate cost per square metre at the required dry film thickness, not per drum.
02

Elongation

on its own can mislead. A very stretchy but thin film can still fail over a crack. Crack bridging, tested at a stated dry film thickness, is more directly linked to field performance. Always check the thickness at which a result was obtained.
03

Drying times

(touch dry, recoat, full cure, rain resistance) are given at a stated temperature and humidity. In hot climates surface drying is quicker but the risk of skinning over trapped moisture rises; in cool damp weather all times lengthen.

Dry film thickness as part of the specification

Industry guidance on liquid membranes recommends that designers specify the dry film thickness rather than only the consumption rate, and that installers verify wet film thickness during application. The data sheet should give the consumption needed to reach the stated DFT on a smooth surface.

What to include in an enquiry

State the use (below ground, wet area, roof under cover), the standard you need the product declared against, and the target dry film thickness. Ask for the data sheet with the values above, the safety data sheet and a certificate of analysis for each batch, showing at least density and solids. Nuroil supplies elastomeric SBS bitumen coating with these documents and third-party inspection on request through request a quote.

PRODUCTS IN THIS GUIDE
KEEP READING

More from the knowledge centre.

STILL HAVE A QUESTION?

Ask the people who trade it every day.

Our trade managers answer technical and commercial questions about grades, specifications, packing and shipping.

LET’S TALK ABOUT YOUR REQUIREMENTS

Your next shipment starts here.

Request a quote