Black bitumen paint is a simple product: bitumen dissolved in a hydrocarbon solvent, sometimes with fillers or resins added. Even so, data sheets from different producers can look quite different. This guide explains the parameters you will usually find and how to use them to compare products or check a delivery.

Composition

Most black bitumen paints are described as bitumen cut back with white spirit or a similar petroleum hydrocarbon solvent, in the C9 to C12 range. Once applied, the solvent evaporates and leaves a black bitumen film. Some products are described as suitable for contact with drinking water; these are made and certified for that purpose and should not be confused with general-purpose grades.

Key parameters

ParameterTypical published valuesWhat it tells you
Solids content (by weight)Around 50% in some productsHow much bitumen remains as film per kilogram
Volume solidsAround 39% in one listed productUsed to calculate dry film thickness from wet film
Relative densityAbout 0.9Converts litres to kilograms for ordering and freight
Flash pointAround 40 °C for white-spirit-based productsFlammability classification for storage and transport
Coverage on concreteAbout 4–6 m² per litre per coatVaries with porosity
Coverage on metalAbout 8–11 m² per litre per coatSmooth surfaces absorb less
Drying and recoatFrom 2–6 hours dry to 16–24 hours recoatDepends on product, film thickness, temperature and airflow

The values above are drawn from several manufacturers' published data and are for orientation only. Use the specific product's sheet.

Working out film thickness

Where a data sheet gives volume solids, you can estimate dry film thickness from the wet film. For example, a wet film of 100 µm with 39% volume solids leaves about 39 µm dry. Theoretical spreading rate in m² per litre equals volume solids (%) × 10 ÷ dry film thickness (µm). Real coverage is lower because of surface roughness, absorption and losses, which is why practical figures on concrete are much lower than on steel.

Coverage stated by weight

Some producers quote consumption in grams per square metre rather than square metres per litre, for example 100–150 g/m² per coat on metal and 250–300 g/m² on concrete. Use the density to convert. A product with higher apparent coverage may simply be applied as a thinner film. When comparing quotations, the fairer measure is cost per square metre at the dry film thickness the job needs, not cost per litre.

Standards

Black bitumen coatings may be made to national standards. BS 3416, for example, specifies bitumen-based solvent-borne coatings for cold application by brush, spray, roller or dip, for corrosion protection and waterproofing of iron and steel and other substrates, with types and classes suitable for potable water tanks as well as general use. The standard notes that such coatings are not intended for hot surfaces or for contact with mineral oils or paint solvents. Where a product claims compliance with a standard, ask which type and class.

Limitations section

Read the limitations as carefully as the figures. Common warnings include:

  • The paint does not inhibit rust; treat steel first.
  • It may bleed through paints applied over it.
  • It is not resistant to heat, mineral oils or solvents.
  • Porous surfaces should be primed.

Checking a delivery against the data sheet

Ask that the batch CoA reports at least solids content, density or specific gravity and appearance, and compare them with the approved TDS. Make sure the SDS matches the solvent type actually supplied, as this affects storage and transport. Nuroil provides a CoA with every delivery of bitumen paint and can arrange third-party inspection on request.