Technical document

· PDF

Tell us who you are and the document downloads straight away. We use these details only to follow up on your requirement.

Samples & documents

What can we send you?

Tick what you need
Request a quote
NUROIL / BITUMEN / VISCOSITY GRADE / VG-10

Bitumen VG-10.For cold regions.

Bitumen VG-10 (viscosity grade 10) is a specific type of bitumen used primarily in road construction and waterproofing applications.

  • Viscosity 800–1200 P
  • Penetration 80 min
  • Flash point 220 °C min
  • IS 73:2013
Black steel drums of viscosity grade bitumen on a pallet
StandardIS 73:2013Penetration 80 min (0.1 mm)
VG-10800–1200 PCold regions and low-traffic roads
HazardNot classifiedUN Not regulated cold · UN 3257 when shipped hot, per SDS
Viscosity at 60 °C800–1200 P
Kinematic viscosity at 135 °C250 cSt min
Penetration at 25 °C80 min (0.1 mm)
Flash point220 °C min
Softening point40 °C min
Switch gradeThe viscosity grades
Compare the viscosity grades
01 THE GRADE

What is Bitumen VG-10?

Bitumen VG-10 (viscosity grade 10) is a specific type of bitumen used primarily in road construction and waterproofing applications. This grade is suitable for use in areas with colder temperatures where softer bitumen is required for road construction and maintenance.

The main application of Bitumen VG-10 is in road construction, particularly in cold climates or regions with lower temperatures.

Bitumen VG-10 is primarily used in road surfacing, cold-weather applications, and as a primer for waterproofing projects.

Bitumen VG-10 is supplied to IS 73:2013, the Indian specification for viscosity-graded paving bitumen, with absolute viscosity at 60 °C as the grading test.

Share the grade, standard and edition your project names and our team will confirm the fit and the supply arrangement.

Identity
Standard
IS 73:2013
Viscosity at 60 °C
800–1200 P
Penetration
80 min (0.1 mm)
Viscosity grade bitumen · IS 73:2013
Why Bitumen VG-10
  • AC and VG grades, one supplierQuote against ASTM D3381 AC grades or IS 73:2013 VG grades, matched to the standard and edition named in your project documents.
  • Every batch tested at 60 °CAbsolute viscosity is measured with a vacuum capillary viscometer alongside the other limits of the specified grade, with results on the CoA.
  • Full shipping documentationA Certificate of Analysis travels with every shipment. Certificate of Origin and MSDS are arranged on request.
  • UAE load portsLoading from UAE ports with FOB as standard; CFR and CIF destination-port offers are quoted on request.
  • Packed for your siteNew steel drums for containerised supply, jumbo bags for compatible grades, or heated bulk by vessel and tanker for high-volume receivers.
  • Trade risk handledThe Nuroil team manages transport, insurance, logistics and foreign-currency payments, and can discuss financing options with overseas buyers.
What Nuroil does on every order

Why source Bitumen VG-10 from Nuroil?

  • Tested at 60 °C

    Absolute viscosity and the other limits of the grade on every batch, reported on the Certificate of Analysis.

  • ASTM or IS, as specified

    Share the standard and edition your project names; AC and VG classifications are not treated as automatically interchangeable.

  • Drum to bulk

    New steel drums, jumbo bags, tanker vessel or tank container, matched to your receiving facilities.

  • FOB, CFR or CIF

    FOB from UAE ports; CFR and CIF destination-port offers on request.

02 TECHNICAL DATA

Catalogue specification.

Penetration at 25 °C, 100 g, 5 s
80 (0.1 mm) minASTM D5
Absolute viscosity at 60 °C
800–1200 PASTM D2171
Kinematic viscosity at 135 °C
250 cSt minASTM D2170
Flash point, Cleveland open cup
220 °C minASTM D92
Solubility in trichloroethylene
99.0% wt minASTM D2042
Softening point (ring and ball)
40 °C minASTM D36
Rolling thin-film oven test (RTFOT)
Residue conditioningASTM D1754
Ductility at 25 °C, 5 cm/min, after RTFOT
75 cm minASTM D113
Retained penetration, after RTFOT
40% minASTM D5
03 APPLICATIONS

Where it is used.

04 SAFETY & HANDLING

Not classified cold. Handled hot, with care.

Viscosity grade bitumen is generally not classified as hazardous when cold. It is stored, pumped and loaded hot, and the Safety Data Sheet for the offered grade decides; review it before first handling.

Not classified
  • GHS Generally not classified as hazardous when cold. Check the SDS for the offered grade.
  • Hot product Handled hot: contact causes severe burns, and hydrogen sulphide can collect in tank headspace. Per SDS.
UN
Not regulated cold · UN 3257 when shipped hot, per SDS
Transport
Elevated temperature liquid, Class 9, when hot · per SDS
  1. 01
    Hot product burns

    Contact with hot bitumen causes severe burns. Wear heat-resistant gloves, face protection and covering clothing when handling it hot.

  2. 02
    Hydrogen sulphide in the headspace

    H₂S can collect in the headspace of heated tanks and tankers. Ventilate and test the atmosphere before opening or entry, per SDS.

  3. 03
    Avoid overheating

    Prolonged excessive heat accelerates ageing and hardening before application. Use the heating range appropriate to the grade.

  4. 04
    Follow the SDS

    Classification, first aid and fire-fighting measures are on the Safety Data Sheet for the offered grade.

Plan heating and handling.
Before it arrivesHeating and receiving confirmed

Confirm heating, storage and handling requirements for your grade and packing format before shipment arrives. Hot bulk bitumen requires suitable heated receiving facilities.

  • Grade temperatureUse the heating and application range appropriate to the selected grade.
  • Avoid overheatingProlonged excessive heat accelerates ageing and hardening before application.
  • Modifier compatibilityConfirm compatibility with project-required polymers or additives before site blending.
  • Receiving facilitiesHot bulk bitumen requires suitable heated storage, pumps and safe transfer equipment.
Standards and test methods.
  • HS code2713.20
  • Transport, coldNot regulated
  • Transport, hotUN 3257
IS 73:2013
Indian paving-bitumen specification for VG grades
ASTM D2171 · IS 1206 Part 2
Absolute viscosity at 60 °C by vacuum capillary viscometer, the grading test
ASTM D2170 · IS 1206 Part 3
Kinematic viscosity at 135 °C
ASTM D5 / ASTM D36
Penetration and ring-and-ball softening point
ASTM D92 / ASTM D2042
Flash point and solubility
ASTM D1754 / ASTM D113
Thin-film oven residue and its ductility
National road authority specification
May add project-specific limits or reference a national variant; confirm the exact standard, grade and edition before ordering
05 PACKING OPTIONS

Drums, jumbo bags or bulk.

Packing availability is confirmed for Bitumen VG-10 and the offered source. Container loads in the planner are typical planning figures; the offer confirms them.

Plan your order

How many containers is that?

Typical loads used for planning. Your offer confirms the exact packing and load for the product and source.

720 ft containers
drums
556
Last 20 ft container
94% full
  • Minimum orderBy grade and packingShare your requirement; feasibility is confirmed with the quote
  • BulkTanker vessel or tank containerPer vessel hold capacity, confirmed at booking
  • DocumentsCoA with every batchSDS and Certificate of Origin on request
06 BEFORE YOU ORDER

Frequently asked questions.

01What does VG-10 mean?

VG means Viscosity Grade under IS 73:2013. VG-10 permits viscosity of 800–1200 poises at 60°C.

02Does a grade name establish product suitability?

No. Compare the complete offered specification with the project requirements and applicable standard.

03What packing formats are available?

Drums, jumbo bags and bulk supply are available depending on grade, quantity and destination facilities.

04What documents come with each shipment?

Every shipment includes a Certificate of Analysis. Certificate of Origin, MSDS and third-party inspection are available on request.

05What Incoterms do you offer?

FOB is commonly quoted from UAE ports; CFR and CIF destination-port offers are available.

06How is the grade tested before shipment?

Each batch is tested for absolute viscosity at 60°C with a vacuum capillary viscometer (ASTM D2171, or IS 1206 Part 2 for IS 73 grades), alongside the other limits of the specified grade, with results on the CoA.

FROM SPECIFICATION TO SUPPLY

Discuss your Bitumen VG-10 requirement.

Include the grade, ASTM or IS standard, quantity, destination, specification and packing preference. Our team replies with a tailored offer. We reply with a firm FOB, CFR or CIF offer, usually within 24 hours.

  • Grade plus standard, ASTM or IS
  • Drums, jumbo bags or bulk
  • FOB, CFR or CIF
Request a quote
LET’S TALK ABOUT YOUR REQUIREMENTS

Your next shipment starts here.

Request a quote