Technical document

· PDF

Tell us who you are and the document downloads straight away. We use these details only to follow up on your requirement.

Samples & documents

What can we send you?

Tick what you need
Request a quote
NUROIL / BITUMEN / VISCOSITY GRADE / AC-10

Bitumen AC-10.Added stiffness.

Bitumen AC-10 is asphalt cement of viscosity grade 10, used in road construction where greater stiffness and strength are needed for heavier traffic or harsher conditions.

  • Viscosity 1000 ± 200 P
  • Penetration 70 min
  • Flash point 219 °C min
  • ASTM D3381 · AC
Black steel drums of viscosity grade bitumen on a pallet
StandardASTM D3381 · ACPenetration 70 min (0.1 mm)
AC-101000 ± 200 PCooler climates and lighter traffic
HazardNot classifiedUN Not regulated cold · UN 3257 when shipped hot, per SDS
Viscosity at 60 °C1000 ± 200 P
Kinematic viscosity at 135 °C150 cSt min
Penetration at 25 °C70 min (0.1 mm)
Flash point219 °C min
StandardASTM D3381-09
Switch gradeThe viscosity grades
Compare the viscosity grades
01 THE GRADE

What is Bitumen AC-10?

Bitumen AC-10 is asphalt cement of viscosity grade 10, used in road construction where greater stiffness and strength are needed for heavier traffic or harsher conditions.

The main application of Bitumen AC-10 is in high-traffic road construction and paving projects where stiffer asphalt is required to handle heavy loads and warmer climates.

The main focus of AC-10 is to provide strength and durability in situations where heavy traffic and warmer temperatures are significant factors.

Bitumen AC-10 is supplied to ASTM D3381, graded on the viscosity of the original asphalt cement at 60 °C, tested to ASTM D2171.

Share the grade, standard and edition your project names and our team will confirm the fit and the supply arrangement.

Identity
Standard
ASTM D3381 · AC
Viscosity at 60 °C
1000 ± 200 P
Penetration
70 min (0.1 mm)
Viscosity grade bitumen · ASTM D3381 AC
Why Bitumen AC-10
  • AC and VG grades, one supplierQuote against ASTM D3381 AC grades or IS 73:2013 VG grades, matched to the standard and edition named in your project documents.
  • Every batch tested at 60 °CAbsolute viscosity is measured with a vacuum capillary viscometer alongside the other limits of the specified grade, with results on the CoA.
  • Full shipping documentationA Certificate of Analysis travels with every shipment. Certificate of Origin and MSDS are arranged on request.
  • UAE load portsLoading from UAE ports with FOB as standard; CFR and CIF destination-port offers are quoted on request.
  • Packed for your siteNew steel drums for containerised supply, jumbo bags for compatible grades, or heated bulk by vessel and tanker for high-volume receivers.
  • Trade risk handledThe Nuroil team manages transport, insurance, logistics and foreign-currency payments, and can discuss financing options with overseas buyers.
What Nuroil does on every order

Why source Bitumen AC-10 from Nuroil?

  • Tested at 60 °C

    Absolute viscosity and the other limits of the grade on every batch, reported on the Certificate of Analysis.

  • ASTM or IS, as specified

    Share the standard and edition your project names; AC and VG classifications are not treated as automatically interchangeable.

  • Drum to bulk

    New steel drums, jumbo bags, tanker vessel or tank container, matched to your receiving facilities.

  • FOB, CFR or CIF

    FOB from UAE ports; CFR and CIF destination-port offers on request.

02 TECHNICAL DATA

Catalogue specification.

Viscosity at 60 °C
1000 ± 200 PASTM D2171
Kinematic viscosity at 135 °C
150 cSt minASTM D2170
Penetration at 25 °C, 100 g, 5 s
70 (0.1 mm) minASTM D5
Flash point, Cleveland open cup
219 °C minASTM D92
Solubility in trichloroethylene
99.0% wt minASTM D2042
Viscosity at 60 °C, after TFOT
5000 P maxASTM D2170
Ductility at 25 °C, 5 cm/min, after TFOT
50 cm minASTM D113
03 APPLICATIONS

Where it is used.

04 SAFETY & HANDLING

Not classified cold. Handled hot, with care.

Viscosity grade bitumen is generally not classified as hazardous when cold. It is stored, pumped and loaded hot, and the Safety Data Sheet for the offered grade decides; review it before first handling.

Not classified
  • GHS Generally not classified as hazardous when cold. Check the SDS for the offered grade.
  • Hot product Handled hot: contact causes severe burns, and hydrogen sulphide can collect in tank headspace. Per SDS.
UN
Not regulated cold · UN 3257 when shipped hot, per SDS
Transport
Elevated temperature liquid, Class 9, when hot · per SDS
  1. 01
    Hot product burns

    Contact with hot bitumen causes severe burns. Wear heat-resistant gloves, face protection and covering clothing when handling it hot.

  2. 02
    Hydrogen sulphide in the headspace

    H₂S can collect in the headspace of heated tanks and tankers. Ventilate and test the atmosphere before opening or entry, per SDS.

  3. 03
    Avoid overheating

    Prolonged excessive heat accelerates ageing and hardening before application. Use the heating range appropriate to the grade.

  4. 04
    Follow the SDS

    Classification, first aid and fire-fighting measures are on the Safety Data Sheet for the offered grade.

Plan heating and handling.
Before it arrivesHeating and receiving confirmed

Confirm heating, storage and handling requirements for your grade and packing format before shipment arrives. Hot bulk bitumen requires suitable heated receiving facilities.

  • Grade temperatureUse the heating and application range appropriate to the selected grade.
  • Avoid overheatingProlonged excessive heat accelerates ageing and hardening before application.
  • Modifier compatibilityConfirm compatibility with project-required polymers or additives before site blending.
  • Receiving facilitiesHot bulk bitumen requires suitable heated storage, pumps and safe transfer equipment.
Standards and test methods.
  • HS code2713.20
  • Transport, coldNot regulated
  • Transport, hotUN 3257
ASTM D3381 · AASHTO M 226
ASTM viscosity-graded paving bitumen specification and its AASHTO equivalent, graded on the original asphalt
ASTM D2171
Absolute viscosity at 60 °C by vacuum capillary viscometer, the grading test
ASTM D2170
Kinematic viscosity at 135 °C
ASTM D5 / ASTM D113
Penetration and ductility
ASTM D92 / ASTM D2042
Flash point and solubility
National road authority specification
May add project-specific limits or reference a national variant; confirm the exact standard, grade and edition before ordering
05 PACKING OPTIONS

Drums, jumbo bags or bulk.

Packing availability is confirmed for Bitumen AC-10 and the offered source. Container loads in the planner are typical planning figures; the offer confirms them.

Plan your order

How many containers is that?

Typical loads used for planning. Your offer confirms the exact packing and load for the product and source.

720 ft containers
drums
556
Last 20 ft container
94% full
  • Minimum orderBy grade and packingShare your requirement; feasibility is confirmed with the quote
  • BulkTanker vessel or tank containerPer vessel hold capacity, confirmed at booking
  • DocumentsCoA with every batchSDS and Certificate of Origin on request
06 BEFORE YOU ORDER

Frequently asked questions.

01What does AC-10 mean?

AC means asphalt cement, graded on the original binder under ASTM D3381. The number gives its viscosity at 60°C in hundreds of poise: AC-10 permits 1000 ± 200 poise. Higher numbers are thicker.

02Does a grade name establish product suitability?

No. Compare the complete offered specification with the project requirements and applicable standard.

03What packing formats are available?

Drums, jumbo bags and bulk supply are available depending on grade, quantity and destination facilities.

04What documents come with each shipment?

Every shipment includes a Certificate of Analysis. Certificate of Origin, MSDS and third-party inspection are available on request.

05What Incoterms do you offer?

FOB is commonly quoted from UAE ports; CFR and CIF destination-port offers are available.

06How is the grade tested before shipment?

Each batch is tested for absolute viscosity at 60°C with a vacuum capillary viscometer (ASTM D2171), alongside the other limits of the specified grade, with results on the CoA.

FROM SPECIFICATION TO SUPPLY

Discuss your Bitumen AC-10 requirement.

Include the grade, ASTM or IS standard, quantity, destination, specification and packing preference. Our team replies with a tailored offer. We reply with a firm FOB, CFR or CIF offer, usually within 24 hours.

  • Grade plus standard, ASTM or IS
  • Drums, jumbo bags or bulk
  • FOB, CFR or CIF
Request a quote
LET’S TALK ABOUT YOUR REQUIREMENTS

Your next shipment starts here.