Technical phosphoric acid 85%: specification parameters and what they mean

A parameter-by-parameter guide to the certificate of analysis for 85% technical phosphoric acid: assay, density, colour, iron, chloride, sulphate and more.

Written by the Nuroil trade desk, Sharjah

On this page · 6 sections
  1. 01Basic physical properties
  2. 02The specification sheet line by line
  3. 03Which parameters matter for which use
  4. 04Checking a delivery
  5. 05Safety reminders
  6. 06Building your own specification

Technical phosphoric acid at 85% H3PO4 is the most widely traded industrial form of the acid. Its certificate of analysis usually lists between six and twelve parameters. Each one tells the buyer something about strength, purity or suitability for a particular process. This guide explains what each line means and which ones deserve attention for common uses. Exact limits vary by producer and contract, so treat it as a guide to reading a specification rather than a substitute for one.

Basic physical properties

At 85% the acid is a clear, colourless, syrupy liquid with no smell. Its density at 25 °C is about 1.685 g/cm³, so a litre weighs close to 1.7 kg. It mixes with water in all proportions, giving off a small amount of heat. A property that surprises many buyers is its freezing behaviour: above about 62.5% strength the freezing point rises with concentration, and 85% acid can crystallise at around 21 °C. Slow cooling and supercooling mean it often stays liquid below that, but a seed crystal or vibration can start solidification in cold storage or winter transit.

The specification sheet line by line

ParameterWhat it tells youWhy it matters
Assay (H3PO4, %)Acid strength by titrationSets dosing and value; 85% is standard, 75% also common
P2O5 (%)Same strength expressed as oxideAbout 61.6% at 85% H3PO4; useful when comparing with fertilizer acid
Density or specific gravityQuick check of concentrationEasy to verify on receipt with a hydrometer
Colour (APHA or Pt-Co)Visual purityHigh colour suggests organic contamination or poorer purification
Iron (Fe)Metallic impurityCarries into phosphating baths and phosphate salts; can discolour products
Chloride (Cl)Halide impurityPromotes pitting of stainless steel and metal parts being treated
Sulphate (SO4)Residue of the wet processAffects salt manufacture and some phosphating chemistry
Fluoride (F)Residue from phosphate rockCorrosive to glass and equipment; limited tightly in food uses
Heavy metals (as Pb) and arsenic (As)Toxic trace elementsCritical for food, feed, water treatment and detergent uses
Calcium, magnesium, other cationsPurification qualityCan form precipitates when the acid is neutralised
Turbidity or suspended matterClarityShould be clear; haze may indicate precipitates or contamination

Which parameters matter for which use

  • Metal treatment and phosphating: assay, iron and chloride. Chloride in particular undermines corrosion performance.
  • Detergent and cleaner formulation: assay, colour and iron, because finished products are often clear liquids.
  • Water treatment: arsenic and heavy metals, and any requirement of the drinking-water chemical standard that applies in your market.
  • Phosphate salt manufacture: sulphate, fluoride, heavy metals and cations, since they carry into the salt.

Checking a delivery

On arrival, compare the batch number on the packs with the certificate and check the seal on each container. A simple density measurement at a known temperature confirms the concentration is in the right range. If crystals are present, the acid must be gently warmed and mixed before sampling, because the first liquid drawn from a partly frozen container is not representative. For contract disputes, agree in advance on the sampling point, the method, and the laboratory that will act as referee.

Assay tells you how strong the acid is. Iron, chloride, fluoride and heavy metals tell you whether it will work in your process.

Safety reminders

Phosphoric acid causes severe burns to skin and eyes. Mist from heated or sprayed acid irritates the respiratory tract; NIOSH sets a recommended exposure limit of 1 mg/m³ as an eight-hour average and 3 mg/m³ short term. Use goggles or a face shield, acid-resistant gloves and apron, and keep eyewash close to the sampling point. Follow the product SDS.

Building your own specification

When requesting technical phosphoric acid, give the assay you need, the maximum values for the impurities relevant to your use, the test methods if you have preferred ones, and the packing. Ask for the CoA with every batch and a sample if you are qualifying a new source. Nuroil provides a CoA with every delivery and can arrange third-party inspection on request. Use the quote request form or contact us to discuss limits.