Industrial nitric acid combines two hazards: it is highly corrosive to skin, eyes and many materials, and it is an oxidiser that can ignite or intensify the burning of combustible materials. Its fumes are toxic. This guide summarises good practice for sites that receive, store and use 55 to 68% acid. It is general guidance only; follow the product SDS, your local regulations and your site risk assessment.
Health hazards and exposure limits
Liquid nitric acid causes severe burns that may not be painful at first and stain the skin yellow. Splashes to the eye can cause permanent damage. Vapour and mist irritate the eyes and airways, and nitrogen oxides released from the acid can cause lung injury that appears hours after exposure. NIOSH recommends an exposure limit of 2 ppm as an 8-hour average and 4 ppm as a short-term limit; the level considered immediately dangerous to life or health is 25 ppm.
Protective equipment
- Chemical splash goggles plus a full face shield when transferring or sampling.
- Acid-resistant gloves, apron or suit and boots, selected for nitric acid at the strength handled; check the glove maker's data, as many common glove materials are degraded.
- Respiratory protection suited to acid gases and nitrogen oxides where ventilation cannot control exposure, as set out in the SDS.
- An emergency shower and eyewash station close to every handling point, tested regularly.
Storage rules
- Store in a cool, dry, ventilated area, out of direct sun, on an acid-resistant floor with a bund able to hold the largest container or tank.
- Segregate from combustible materials (wood, paper, oils, solvents such as ethyl acetate or alcohols), from metal powders, from alkalis and from reducing agents.
- Do not store on wooden pallets or near cardboard if leaks are possible; use acid-resistant plastic pallets or stands.
- Keep containers closed and labelled. Inspect plastic drums and IBCs for embrittlement, discolouration or bulging, and observe their approved use period.
- Vent bulk tanks to a safe place or a scrubber.
Transfer and dilution
Use pumps, hoses and fittings made from compatible materials, typically stainless steel 304L or fluoropolymers. Avoid pouring by hand from drums. When diluting, always add acid slowly to water with mixing; adding water to acid can boil and spatter. Never mix nitric acid with organic solvents, other acids or cleaning chemicals unless the procedure has been specifically assessed.
Spills
- Evacuate the immediate area and keep upwind; brown fumes indicate nitrogen oxides.
- Responders should wear full acid protection and respiratory protection as specified in the SDS.
- Contain the spill with inert absorbent such as dry sand or a commercial acid absorbent. Do not use sawdust, rags or other combustible absorbents.
- Neutralise cautiously with a weak alkali such as soda ash or lime, expecting heat and gas release, then collect for disposal under local rules.
- Prevent entry to drains and water courses.
Transport classification
| Concentration | UN number and class | Packing group |
|---|---|---|
| Below 65% | UN 2031, Class 8 (corrosive) | II |
| 65% to 70% | UN 2031, Class 8 with subsidiary hazard 5.1 (oxidiser) | II |
The oxidiser subsidiary label for acid at 65% and above affects segregation on ships and in warehouses, as well as labelling. Check the current IMDG Code and regional road rules for the exact entry. Commercial nitric acid is commonly shipped in approved plastic drums, IBCs or stainless steel ISO tank containers.
Keep nitric acid away from anything that burns, add it to water and not the reverse, and never soak up a spill with sawdust.
Supply checklist
Before the first delivery, obtain the SDS, confirm the UN classification for the strength ordered, agree the packing type and confirm that your store, bund and PPE are ready. Nuroil provides the SDS on request and a CoA with every delivery, and can arrange third-party inspection. Use the quote request form to share concentration, packing and destination.