Nitric acid behaves differently from most mineral acids. It is strongly oxidising, so it attacks some materials that resist hydrochloric or sulphuric acid, yet it helps protect certain metals by building up their oxide films. Choosing materials for tanks, pipes, pumps and seals therefore needs specific nitric acid data. This guide summarises general practice for 55 to 68% acid at ambient storage temperatures. Final selection should always be confirmed against corrosion data for the actual concentration, temperature and impurities, and with the equipment supplier.
Stainless steels
304L is the standard choice
Molybdenum offers no advantage
Watch temperature and condensation
Weld quality
Metals to avoid
- Carbon steel is rapidly attacked by dilute and intermediate-strength nitric acid and is not suitable for the 55 to 68% range.
- Aluminium resists only very concentrated acid (above about 80%) at room temperature. It is attacked by the commercial 55 to 68% grades.
- Copper, brass, zinc and galvanised steel are attacked and should not be used in contact with the acid or its fumes.
Plastics and linings
| Material | General suitability with 55 to 68% nitric acid |
|---|---|
| PTFE and other fully fluorinated polymers | Excellent; used for gaskets, linings, hoses and valve seats |
| PVDF | Generally good; used for piping and pump components, within the supplier's temperature limits |
| Polyethylene (HDPE) | Used for drums and IBCs approved for the product, but oxidising acid gradually degrades it; observe the packaging's approved use period |
| PVC and polypropylene | Limited at these strengths; check supplier data before use |
| Natural rubber, nitrile, neoprene, nylon | Not suitable; attacked by strong nitric acid |
Seals, gaskets and small parts
Gaskets are a frequent weak point. PTFE or PTFE-enveloped gaskets are widely used. Some fluoroelastomers are suitable only for limited concentrations and temperatures, so check the compound data. Avoid graphite, rubber and fibre gaskets unless the manufacturer confirms they are suitable. Instruments, level gauges, sample valves and hose couplings should all be checked; a single brass fitting can fail and cause a leak.
For storage tanks and lines in commercial nitric acid, 304L stainless steel with PTFE seals is the usual starting point; carbon steel, aluminium, copper alloys and ordinary rubbers are not.
Design and inspection points
- Keep tanks at ground level inside a bund, with access for inspection.
- Vent tanks to a safe place or a scrubber, using vent materials that resist fumes.
- Inspect welds, nozzles and the vapour space regularly; corrosion often starts where vapour condenses.
- Keep organic materials, including oils and lubricants, out of the system.
Supply considerations
Tell your supplier what your receiving equipment is made of, so packing and hoses are compatible, and ask for impurity results such as chloride that affect your materials. Nuroil can provide the SDS and CoA for each delivery. Contact us to discuss packing that suits your site.