Materials of construction for nitric acid tanks, pipes and seals

Which metals, plastics and seal materials suit 55-68% nitric acid, why 304L is the usual tank choice and which common materials fail quickly.

Written by the Nuroil trade desk, Sharjah

On this page · 6 sections
  1. 01Stainless steels
  2. 02Metals to avoid
  3. 03Plastics and linings
  4. 04Seals, gaskets and small parts
  5. 05Design and inspection points
  6. 06Supply considerations

Nitric acid behaves differently from most mineral acids. It is strongly oxidising, so it attacks some materials that resist hydrochloric or sulphuric acid, yet it helps protect certain metals by building up their oxide films. Choosing materials for tanks, pipes, pumps and seals therefore needs specific nitric acid data. This guide summarises general practice for 55 to 68% acid at ambient storage temperatures. Final selection should always be confirmed against corrosion data for the actual concentration, temperature and impurities, and with the equipment supplier.

Stainless steels

01

304L is the standard choice

Low-carbon austenitic stainless steel type 304L has long been the most common material for nitric acid storage tanks, piping and process equipment. Its chromium content forms a stable passive film in oxidising acid. The low carbon content reduces the risk of intergranular attack next to welds, where carbide formation during welding can deplete chromium at grain boundaries.
02

Molybdenum offers no advantage

Unlike in chloride-containing environments, molybdenum-bearing grades such as 316 and 316L do not perform better than 304L in pure nitric acid, and some data show them performing slightly worse. They are only considered where nitric acid is mixed with other acids or chlorides, and then only after testing.
03

Watch temperature and condensation

304L performs well with 65% acid up to around 100 °C, but corrosion increases at higher temperatures, on hot metal surfaces and where nitrogen oxide gases condense. Special nitric acid grades of stainless steel and other alloys are used in those zones in production plants.
04

Weld quality

Materials for nitric acid service are often tested for intergranular corrosion resistance by the Huey test, which exposes samples to boiling 65% nitric acid over several periods. Requesting this test, or certified material that has passed it, is common for critical equipment.

Metals to avoid

  • Carbon steel is rapidly attacked by dilute and intermediate-strength nitric acid and is not suitable for the 55 to 68% range.
  • Aluminium resists only very concentrated acid (above about 80%) at room temperature. It is attacked by the commercial 55 to 68% grades.
  • Copper, brass, zinc and galvanised steel are attacked and should not be used in contact with the acid or its fumes.

Plastics and linings

MaterialGeneral suitability with 55 to 68% nitric acid
PTFE and other fully fluorinated polymersExcellent; used for gaskets, linings, hoses and valve seats
PVDFGenerally good; used for piping and pump components, within the supplier's temperature limits
Polyethylene (HDPE)Used for drums and IBCs approved for the product, but oxidising acid gradually degrades it; observe the packaging's approved use period
PVC and polypropyleneLimited at these strengths; check supplier data before use
Natural rubber, nitrile, neoprene, nylonNot suitable; attacked by strong nitric acid

Seals, gaskets and small parts

Gaskets are a frequent weak point. PTFE or PTFE-enveloped gaskets are widely used. Some fluoroelastomers are suitable only for limited concentrations and temperatures, so check the compound data. Avoid graphite, rubber and fibre gaskets unless the manufacturer confirms they are suitable. Instruments, level gauges, sample valves and hose couplings should all be checked; a single brass fitting can fail and cause a leak.

For storage tanks and lines in commercial nitric acid, 304L stainless steel with PTFE seals is the usual starting point; carbon steel, aluminium, copper alloys and ordinary rubbers are not.

Design and inspection points

  • Keep tanks at ground level inside a bund, with access for inspection.
  • Vent tanks to a safe place or a scrubber, using vent materials that resist fumes.
  • Inspect welds, nozzles and the vapour space regularly; corrosion often starts where vapour condenses.
  • Keep organic materials, including oils and lubricants, out of the system.

Supply considerations

Tell your supplier what your receiving equipment is made of, so packing and hoses are compatible, and ask for impurity results such as chloride that affect your materials. Nuroil can provide the SDS and CoA for each delivery. Contact us to discuss packing that suits your site.