On a certificate of analysis for 99.5% ethyl acetate, purity gets most of the attention. Yet many complaints from users trace back to two smaller numbers further down the sheet: water content and acidity. Both are linked, both can rise after the solvent leaves the producer, and both matter far more in some applications than in others.
How the two are connected
Ethyl acetate is an ester made from ethanol and acetic acid. The reaction that forms it can also run backwards. When water is present, ethyl acetate slowly hydrolyses back into ethanol and acetic acid. Acids and especially bases speed this up, and so does heat.
In practice this means water is not just a passive impurity. A batch that picks up moisture will, over time, also show higher acidity and a little more free ethanol. That is why specifications such as ASTM D4614, which covers ethyl acetate grades used in paints and coatings, test for water, acidity and alcohol content side by side.
Where the water comes from
- Production. Water is a by-product of esterification, and drying it out completely is a separate step. Lower-cost material may simply carry more.
- Breathing tanks and drums. As temperatures swing between day and night, containers draw in humid air. Ethyl acetate dissolves a meaningful amount of water (and water dissolves about 8 g of ethyl acetate per 100 mL at 20 °C), so moisture is absorbed rather than settling as a visible layer.
- Wet equipment. Hoses, tankers or drums that were washed with water and not dried properly can add far more than the specification allows in a single transfer.
Why users care
Two-component polyurethane systems
Acid-sensitive chemistry
Odour and corrosion
How the parameters are tested
Water in volatile solvents is normally measured by Karl Fischer titration (ASTM D1364 is the method referenced for this in the ethyl acetate specification). Acidity is measured by titration with a standard alkali and reported either as percent acetic acid or, in food-grade specifications such as the JECFA monograph, as an acid value in mg KOH per gram. Purity and alcohol content are determined by gas chromatography.
Water and acidity are the two parameters most likely to drift between loading and use, so test them on arrival, not only at the producer.
Keeping both low in storage
- Keep drums sealed until use and reseal part-used drums promptly. Store them under cover so rainwater cannot pool on the heads.
- For bulk tanks, consider a dry nitrogen blanket or a desiccant breather instead of an open vent, within the limits of the site's flammable-storage design.
- Make sure transfer hoses, pumps and road tankers are dry and dedicated to compatible solvents.
- Use stock in rotation. Older material is more likely to have picked up moisture and acidity.
- Re-test water by Karl Fischer before using older stock in moisture-sensitive formulations.
What to put in your enquiry
If your process is moisture-sensitive, say so and state the maximum water content and acidity you can accept, along with the test method you will use on arrival. Ask for a certificate of analysis showing actual results for purity, water, acidity and alcohol content, not just "complies". Nuroil supplies a CoA with every delivery and can arrange third-party inspection at loading on request. Send your requirements through the quote request form.