Industrial ethyl acetate is usually traded as a 99.5% minimum grade. The certificate of analysis that comes with it lists ten or so parameters, each with its own test method. This guide explains what each one tells you and why it matters for a solvent user. Exact limits depend on the producer and the standard quoted, so always compare against the specification you agreed.
The reference standard
For solvent use in paints, coatings, inks and adhesives, the most widely referenced standard is ASTM D4614, Standard Specification for Ethyl Acetate (All Grades). It defines the tests required for each grade and points to separate ASTM methods for each measurement. Producers' own sales specifications usually follow the same structure, sometimes with tighter limits.
Parameters on a typical CoA
| Parameter | Common test method | What it tells you |
|---|---|---|
| Purity (assay) | Gas chromatography (ASTM D3545) | Percentage of ethyl acetate; 99.5% minimum for the standard industrial grade |
| Alcohol content | Gas chromatography (ASTM D3545) | Residual ethanol, which affects solvency, evaporation and reaction with isocyanates |
| Water | Karl Fischer titration (ASTM D1364) | Moisture that drives hydrolysis and reacts with isocyanate hardeners |
| Acidity | Titration (ASTM D1613) | Free acid, reported as acetic acid; rises as the ester hydrolyses |
| Colour | Platinum-cobalt scale (ASTM D1209 or D5386) | Should be water-white; colour indicates contamination or degradation |
| Non-volatile matter | Evaporation residue (ASTM D1353) | Heavy residues that would remain in a dried film |
| Specific gravity | Hydrometer or density meter | A quick identity and consistency check; around 0.90 at 20 °C |
| Distillation range | Distillation test | Narrow range around the 77 °C boiling point shows few light or heavy impurities |
| Odour | Comparison against a reference | Detects foreign or residual odours, important for food packaging inks |
Reading the numbers together
Parameters are linked. If water is high, expect acidity and alcohol to rise over time because ethyl acetate hydrolyses to ethanol and acetic acid. A sample that meets purity but fails acidity may simply be old or have been stored in breathing containers. Specific gravity and distillation range act as cross-checks: a low density or a low initial boiling point can point to contamination with a lighter solvent.
Purity alone does not guarantee suitability. A 99.7% material with 0.2% water can perform worse in a two-component polyurethane system than a 99.5% material that is almost dry.
It also helps to know where the sample was taken. A result from the producer's shore tank describes the product before loading; a sample drawn from drums or an ISO tank on arrival shows what you actually received. Differences between the two usually point to moisture pick-up or contamination during packing or transport.
Rounding and reporting
ASTM D4614 follows the common rule that a result is rounded to the last digit of the specification limit before it is compared. A reported 99.46% rounds to 99.5% and conforms to a 99.5% minimum stated to one decimal place. When a precise margin matters, ask for results to an extra decimal place.
Ask for actual results, not "pass", for purity, water, acidity and alcohol; those four tell you most of what you need.
Other grades
- Higher-purity solvent grades (for example 99.8% or 99.9%) are made for electronics, pharmaceuticals and analytical work, with tighter water and residue limits.
- Food and pharmaceutical grades are certified to food or pharmacopoeia monographs that add identity and impurity tests.
- Urethane grade is a term some users apply to ethyl acetate with very low water and alcohol for isocyanate systems; confirm the actual limits rather than relying on the name.
Writing the specification into your order
List the parameters that matter to you with numeric limits and test methods, state which standard applies, and say whether you need results from a loading sample, an independent inspection or both. Nuroil issues a CoA with every delivery and can arrange third-party inspection, CoO and SDS on request. Use the quote request form to send your specification sheet.