Crude glycerine specification: glycerol, ash, MONG and methanol

A reference to the parameters on a crude glycerine specification, including how MONG is calculated and why methanol, ash and pH matter to buyers.

Written by the Nuroil trade desk, Sharjah

On this page · 9 sections
  1. 01The core parameters
  2. 02Glycerol content
  3. 03Ash
  4. 04How MONG is calculated
  5. 05Methanol
  6. 06pH and other items
  7. 07Sampling and testing
  8. 08Handling crude glycerine in bulk
  9. 09Writing a crude glycerine enquiry

Crude glycerine is sold mainly to refiners and industrial users, and its value depends on how much glycerol it contains and how hard the impurities will be to remove. Unlike USP glycerine, there is no single pharmacopoeia standard; trade is based on contract specifications. This guide explains the parameters that usually appear.

The core parameters

ParameterWhat it measuresWhy it matters
Glycerol contentGlycerol as a percentage of the totalMain value driver; refining yield
WaterMoistureDilutes glycerol; energy cost to remove
AshInorganic residue after burning (mostly salts)Fouling and residue in distillation
MONGMatter organic non-glycerolSoaps, fatty acids, esters and other organics to remove
MethanolResidual alcohol from biodieselFlammability, toxicity, process limits
pHAcidity or alkalinityCorrosion and neutralisation demand

Published supplier tables show crude glycerine ranging from about 40% up to 88% glycerol, with water up to around 12% and ash up to a few per cent. Better-stripped biodiesel crude sits at the upper end.

Glycerol content

Usually determined by titration (periodate oxidation) or chromatography. Contracts often price on a stated basis, for example 80% glycerol, with adjustments for actual content. Agree the method, because results can differ.

Ash

Ash shows the salt load: potassium or sodium salts from the biodiesel catalyst and its neutralisation, or sodium chloride in soap-lye crude. High ash means more residue at the refinery and lower distillation yield.

How MONG is calculated

MONG is not measured directly. The withdrawn ISO 2464 method for crude glycerine defined it by difference:

MONG = 100 minus the sum of glycerol, water and ash percentages.

For example, a crude with 82% glycerol, 10% water and 5% ash has a MONG of 3%. A second crude with the same glycerol but 12% water and 2% ash has a MONG of 4%: less salt, but more organic matter to separate. Comparing the full set of numbers, not just glycerol, shows which lot will refine more easily.

Because it is a calculated value, any error in glycerol, water or ash flows straight into MONG. It is still widely used in contracts because a direct measurement of non-volatile organics is slow and less reproducible. High MONG indicates soaps, free fatty acids, methyl esters and other organics that must be removed.

Methanol

Crude from biodiesel plants that do not fully strip methanol can contain enough to lower the flash point and create a flammable atmosphere in tank headspace. Methanol is also toxic. Specifications therefore set a maximum, and sellers should state it on the CoA. Ask for the flash point too if the product is to be shipped or stored in bulk.

pH and other items

  • pH: biodiesel crude may be alkaline if not neutralised, or acidic if over-neutralised. Both affect tank materials.
  • Colour: usually reported but less critical than for refined grades.
  • Source: biodiesel, soap or fat splitting, and the feedstock oil.
  • Sulphur or phosphorus: sometimes requested by refiners, depending on the acid used for neutralisation.

Sampling and testing

Crude glycerine can separate into layers in storage, with fatty matter rising and salts settling. Take samples from several depths or a well-circulated tank, keep sealed retained samples, and agree an independent laboratory in case of dispute.

Handling crude glycerine in bulk

Crude glycerine is viscous and may need gentle heating to discharge in cool weather. Tanks should be compatible with its pH and salt content, and headspace should be treated as potentially flammable until the methanol level is known. Always follow the SDS supplied with the specific lot.

Writing a crude glycerine enquiry

State minimum glycerol, maximum water, ash, MONG and methanol, the pH range and the source. Mention the end use, since refining, energy and feed users have different limits. Nuroil can supply glycerine on request with a CoA per lot and third-party inspection if needed; send your requirements through request a quote.