Oxidised bitumen 95/25 (or blown bitumen 95/25) is a hard, thermally stable grade of bitumen produced by passing air through bitumen at high temperatures.
Oxidised bitumen 95/25 (or blown bitumen 95/25) is a hard, thermally stable grade of bitumen produced by passing air through bitumen at high temperatures. This oxidation process modifies its properties, giving it a higher softening point and lower penetration value, making it resistant to extreme weather and chemical exposure.
Oxidised bitumen 95/25 is ideal for applications where high temperature stability, durability, and waterproofing are essential, making it valuable for infrastructure, industrial, and marine use.
Oxidised bitumen 95/25 is supplied to BS EN 13304-2009, with softening point tested to ASTM D36 and penetration to ASTM D5.
Share the grade, service temperature and end use and our team will confirm the fit and the supply arrangement.
Identity
Softening point
90–100 °C
Penetration
20–30 (0.1 mm)
Standard
BS EN 13304
Oxidised bitumen · BS EN 13304Why Oxidised bitumen 95/25
Grades by softening pointOxidised grades named by softening point and penetration, for roofing, waterproofing, coatings and industrial use.
Every batch testedEach batch is tested for softening point and penetration before it ships, so the grade on the paperwork is the grade supplied.
Full shipping documentationA Certificate of Analysis travels with every shipment. Certificate of Origin and MSDS are arranged on request.
UAE load portsLoading from UAE ports with FOB as standard; CFR and CIF destination-port offers are quoted on request.
Packed for your siteSteel drums for heated handling, bags or blocks for compatible grades, or bulk for receivers with heated infrastructure.
Trade risk handledThe Nuroil team manages transport, insurance, logistics and foreign-currency payments, and can discuss financing options with overseas buyers.
What Nuroil does on every order
Why source Oxidised bitumen 95/25 from Nuroil?
Tested before it ships
Softening point to ASTM D36 and penetration to ASTM D5 on every batch, reported on the Certificate of Analysis.
Matched to the end use
Share the service temperature and end use so the required firmness can be confirmed.
Drums, bags or bulk
Steel drums, 25 kg bags or cartons, jumbo bags, or bulk for heated receivers.
FOB, CFR or CIF
FOB from UAE ports; CFR and CIF destination-port offers on request.
02 TECHNICAL DATA
Catalogue specification.
Penetration at 25 °C, 100 g, 5 s
20–30 (0.1 mm)ASTM D5
Softening point (ring and ball)
90–100 °CASTM D36
Ductility at 25 °C, 5 cm/min
1.5 cm minASTM D113
Solubility in CS₂
99% wt minASTM D4
Flash point, Cleveland open cup
260 °C minASTM D92
Specific gravity at 25 °C
1.00–1.05ASTM D70
Rolling thin-film oven test (RTFOT)
Residue conditioningASTM D1754
Loss on heating, after RTFOT
0.2% wtASTM D6
Oxidised bitumen 95/25 beside the grades nearest to it in softening point. Higher softening points stay firm at higher temperatures; choose by service temperature and end use.
Property
85/40
95/25This page
95/40
115/15
Softening point
80–90 °C
90–100 °C
90–100 °C
110–120 °C
Penetration at 25 °C (0.1 mm)
30–40
20–30
30–40
10–20
Ductility at 25 °C
1.5 cm min
1.5 cm min
1.5 cm min
1.5 cm min
Flash point
260 °C min
260 °C min
260 °C min
260 °C min
Typical use
Roofing, expansion joints and corrosion protection
Roofing, expansion joints and electrical insulation
Roofing, road construction and corrosion protection
High-temperature uses, adhesives and corrosion protection
03 APPLICATIONS
Where it is used.
01
Waterproofing and roofing
Utilised in roofing membranes, felt products, and sealants to protect buildings from moisture and water infiltration.
02
Road maintenance and expansion joints
Acts as a crack sealant and joint filler for highways, bridges, and pavements, ensuring durability and flexibility.
03
Corrosion protection
Coats pipelines, metal structures, and storage tanks to prevent rust and degradation due to environmental factors.
04
Electrical insulation
Provides insulation for electrical cables, transformers, and other equipment, ensuring safety and performance.
05
Construction industry
Used in mastic asphalt and concrete formulations to enhance water resistance and improve overall durability.
06
Marine and offshore applications
Insulates ship decks and protects marine structures from the corrosive effects of saltwater, ensuring long-term performance.
04 SAFETY & HANDLING
Stored and applied hot. Handled with care.
Oxidised bitumen is heated for pumping and application. Follow the Safety Data Sheet for the offered grade, available on request, before first handling.
Per SDS
Hot product Stored and applied hot: follow the PPE, ventilation and burn-prevention guidance on the SDS.
Overheating Excessive heat causes further ageing and fumes. Use grade-specific heating ranges.
HS
2713.20 · petroleum bitumen
SDS
Supplied on request for the offered grade
01
Hot product burns
Follow the PPE, ventilation and burn-prevention guidance on the SDS when handling it hot.
02
Avoid overheating
Excessive heat causes further ageing and fumes. Use grade-specific heating and pumping ranges.
03
Confirm the substrate
Validate adhesion and compatibility before full application.
04
Follow the SDS
Classification, first aid and fire-fighting measures are on the Safety Data Sheet for the offered grade.
Plan heating and application.
Before it arrivesHeating and receiving confirmed
Confirm heating and handling for your grade and packing format before the shipment arrives. Bulk supply needs suitable heated receiving infrastructure.
Grade temperatureUse grade-specific heating and pumping ranges.
Avoid overheatingExcessive heat causes further ageing and fumes.
Confirm substrateValidate adhesion and compatibility before full application.
Use the SDSFollow PPE, ventilation and burn-prevention guidance.
Standards and test methods.
HS code2713.20
SpecificationBS EN 13304
Roofing typesASTM D312
BS EN 13304
Oxidised bitumen specification, 2009 edition, as each grade’s data sheet cites it
ASTM D312
Oxidised asphalt for roofing, Types I–IV
ASTM D36 / ASTM D5
Ring-and-ball softening point and needle penetration at 25 °C
ASTM D113 / D4 / D92 / D70
Ductility, solubility in CS₂, flash point and specific gravity
ASTM D1754 / ASTM D6
Thin-film oven residue and loss on heating
Project specification
May set additional local limits; confirm the exact standard and edition before ordering
05 PACKING OPTIONS
Drums, bags or bulk.
Packing availability is confirmed for Oxidised bitumen 95/25 and the offered source. Container loads in the planner are the published planning figures; the offer confirms them.
Small quantities
Steel drums
New steel drums of 200, 180 or 156 kg, or customised, for containerised supply and heated handling.
Typical loads used for planning. Your offer confirms the exact packing and load for the product and source.
720 ft containers
drums
556
Last 20 ft container
94% full
Minimum orderBy grade and packingShare your requirement; feasibility is confirmed with the quote
BulkHeated receiversFor receivers with suitable heated infrastructure
DocumentsCoA with every batchSDS and Certificate of Origin on request
06 BEFORE YOU ORDER
Frequently asked questions.
01What does 95/25 mean?
The first number approximates softening point in °C and the second penetration in 0.1 mm at 25°C. Oxidised bitumen 95/25 is specified at a softening point of 90–100 °C and penetration 20–30.
02What does oxidised or blown bitumen mean?
Air is blown through hot straight-run bitumen, raising softening point and reducing penetration.
03Can oxidised bitumen be used for road paving?
No. Its firm, high-softening-point character is intended for roofing, waterproofing and coating rather than flexible paving-binder service.
04What documents come with each shipment?
Every shipment includes a Certificate of Analysis. Certificate of Origin and MSDS are available on request.
05What packing formats are available?
Drums, bags or blocks and bulk supply depend on grade, quantity and receiving facilities.
06What Incoterms do you offer?
FOB is commonly quoted from UAE ports; CFR and CIF destination-port offers are available.
07How is it tested before shipment?
Each batch is tested for softening point using ASTM D36 and penetration using ASTM D5.
Include the grade, quantity, destination, specification and packing preference. Share the service temperature and end use so the required firmness can be confirmed. We reply with a firm FOB, CFR or CIF offer, usually within 24 hours.