Technical document

· PDF

Tell us who you are and the document downloads straight away. We use these details only to follow up on your requirement.

Samples & documents

What can we send you?

Tick what you need
Request a quote
NUROIL / BITUMEN / OXIDISED / 85/25

Oxidised 85/25.Rigid and stable.

Oxidised bitumen 85/25 (also called blown bitumen 85/25) is a specialised grade of bitumen that has undergone a controlled oxidation process.

  • Softening point 80–90 °C
  • Penetration 20–30
  • Flash point 260 °C min
  • BS EN 13304
Pencil sketch of rolled bitumen roofing membrane
Softening point80–90 °CStandard BS EN 13304
85/25SP 80–90 °CRoofing, road maintenance and pipe coating
HazardPer SDSHS 2713.20 · petroleum bitumen
Softening point80–90 °C
Penetration at 25 °C20–30 (0.1 mm)
Ductility at 25 °C1.5 cm min
Flash point260 °C min
StandardBS EN 13304-2009
Switch gradeThe oxidised grades
Compare the oxidised grades
01 THE GRADE

What is Oxidised bitumen 85/25?

Oxidised bitumen 85/25 (also called blown bitumen 85/25) is a specialised grade of bitumen that has undergone a controlled oxidation process. This process modifies the physical properties of the bitumen, making it more rigid and less sensitive to temperature changes compared to penetration-grade bitumen.

Oxidised bitumen 85/25 has several industrial applications due to its high softening point, low penetration value, excellent adhesion, and resistance to water and chemicals.

Oxidised bitumen 85/25 is supplied to BS EN 13304-2009, with softening point tested to ASTM D36 and penetration to ASTM D5.

Share the grade, service temperature and end use and our team will confirm the fit and the supply arrangement.

Identity
Softening point
80–90 °C
Penetration
20–30 (0.1 mm)
Standard
BS EN 13304
Oxidised bitumen · BS EN 13304
Why Oxidised bitumen 85/25
  • Grades by softening pointOxidised grades named by softening point and penetration, for roofing, waterproofing, coatings and industrial use.
  • Every batch testedEach batch is tested for softening point and penetration before it ships, so the grade on the paperwork is the grade supplied.
  • Full shipping documentationA Certificate of Analysis travels with every shipment. Certificate of Origin and MSDS are arranged on request.
  • UAE load portsLoading from UAE ports with FOB as standard; CFR and CIF destination-port offers are quoted on request.
  • Packed for your siteSteel drums for heated handling, bags or blocks for compatible grades, or bulk for receivers with heated infrastructure.
  • Trade risk handledThe Nuroil team manages transport, insurance, logistics and foreign-currency payments, and can discuss financing options with overseas buyers.
What Nuroil does on every order

Why source Oxidised bitumen 85/25 from Nuroil?

  • Tested before it ships

    Softening point to ASTM D36 and penetration to ASTM D5 on every batch, reported on the Certificate of Analysis.

  • Matched to the end use

    Share the service temperature and end use so the required firmness can be confirmed.

  • Drums, bags or bulk

    Steel drums, 25 kg bags or cartons, jumbo bags, or bulk for heated receivers.

  • FOB, CFR or CIF

    FOB from UAE ports; CFR and CIF destination-port offers on request.

02 TECHNICAL DATA

Catalogue specification.

Penetration at 25 °C, 100 g, 5 s
20–30 (0.1 mm)ASTM D5
Softening point (ring and ball)
80–90 °CASTM D36
Ductility at 25 °C, 5 cm/min
1.5 cm minASTM D113
Solubility in CS₂
99% wt minASTM D4
Flash point, Cleveland open cup
260 °C minASTM D92
Specific gravity at 25 °C
1.00–1.05ASTM D70
Rolling thin-film oven test (RTFOT)
Residue conditioningASTM D1754
Loss on heating, after RTFOT
0.2% wtASTM D6
03 APPLICATIONS

Where it is used.

04 SAFETY & HANDLING

Stored and applied hot. Handled with care.

Oxidised bitumen is heated for pumping and application. Follow the Safety Data Sheet for the offered grade, available on request, before first handling.

Per SDS
  • Hot product Stored and applied hot: follow the PPE, ventilation and burn-prevention guidance on the SDS.
  • Overheating Excessive heat causes further ageing and fumes. Use grade-specific heating ranges.
HS
2713.20 · petroleum bitumen
SDS
Supplied on request for the offered grade
  1. 01
    Hot product burns

    Follow the PPE, ventilation and burn-prevention guidance on the SDS when handling it hot.

  2. 02
    Avoid overheating

    Excessive heat causes further ageing and fumes. Use grade-specific heating and pumping ranges.

  3. 03
    Confirm the substrate

    Validate adhesion and compatibility before full application.

  4. 04
    Follow the SDS

    Classification, first aid and fire-fighting measures are on the Safety Data Sheet for the offered grade.

Plan heating and application.
Before it arrivesHeating and receiving confirmed

Confirm heating and handling for your grade and packing format before the shipment arrives. Bulk supply needs suitable heated receiving infrastructure.

  • Grade temperatureUse grade-specific heating and pumping ranges.
  • Avoid overheatingExcessive heat causes further ageing and fumes.
  • Confirm substrateValidate adhesion and compatibility before full application.
  • Use the SDSFollow PPE, ventilation and burn-prevention guidance.
Standards and test methods.
  • HS code2713.20
  • SpecificationBS EN 13304
  • Roofing typesASTM D312
BS EN 13304
Oxidised bitumen specification, 2009 edition, as each grade’s data sheet cites it
ASTM D312
Oxidised asphalt for roofing, Types I–IV
ASTM D36 / ASTM D5
Ring-and-ball softening point and needle penetration at 25 °C
ASTM D113 / D4 / D92 / D70
Ductility, solubility in CS₂, flash point and specific gravity
ASTM D1754 / ASTM D6
Thin-film oven residue and loss on heating
Project specification
May set additional local limits; confirm the exact standard and edition before ordering
05 PACKING OPTIONS

Drums, bags or bulk.

Packing availability is confirmed for Oxidised bitumen 85/25 and the offered source. Container loads in the planner are the published planning figures; the offer confirms them.

Plan your order

How many containers is that?

Typical loads used for planning. Your offer confirms the exact packing and load for the product and source.

720 ft containers
drums
556
Last 20 ft container
94% full
  • Minimum orderBy grade and packingShare your requirement; feasibility is confirmed with the quote
  • BulkHeated receiversFor receivers with suitable heated infrastructure
  • DocumentsCoA with every batchSDS and Certificate of Origin on request
06 BEFORE YOU ORDER

Frequently asked questions.

01What does 85/25 mean?

The first number approximates softening point in °C and the second penetration in 0.1 mm at 25°C. Oxidised bitumen 85/25 is specified at a softening point of 80–90 °C and penetration 20–30.

02What does oxidised or blown bitumen mean?

Air is blown through hot straight-run bitumen, raising softening point and reducing penetration.

03Can oxidised bitumen be used for road paving?

No. Its firm, high-softening-point character is intended for roofing, waterproofing and coating rather than flexible paving-binder service.

04What documents come with each shipment?

Every shipment includes a Certificate of Analysis. Certificate of Origin and MSDS are available on request.

05What packing formats are available?

Drums, bags or blocks and bulk supply depend on grade, quantity and receiving facilities.

06What Incoterms do you offer?

FOB is commonly quoted from UAE ports; CFR and CIF destination-port offers are available.

07How is it tested before shipment?

Each batch is tested for softening point using ASTM D36 and penetration using ASTM D5.

FROM SPECIFICATION TO SUPPLY

Discuss your Oxidised bitumen 85/25 requirement.

Include the grade, quantity, destination, specification and packing preference. Share the service temperature and end use so the required firmness can be confirmed. We reply with a firm FOB, CFR or CIF offer, usually within 24 hours.

  • Grade plus application
  • Drums, bags or bulk
  • FOB, CFR or CIF
Request a quote
LET’S TALK ABOUT YOUR REQUIREMENTS

Your next shipment starts here.

Request a quote