Trichloroisocyanuric acid (TCCA) tablets are popular because they dissolve slowly and release chlorine over days. How evenly that chlorine reaches the water depends far more on the device holding the tablets than on the tablets themselves. The same 200 g tablet can give a steady residual in one installation and a bleached liner or corroded heater in another.
Why the dosing device matters
TCCA is only slightly soluble, around 1.2 g in 100 mL of water, and its solution is strongly acidic. Wherever tablets sit, the water immediately around them carries a high concentration of chlorine and a low pH. A good dosing device controls how much water passes over the tablets, mixes that strong solution into the main flow quickly and keeps it away from surfaces and equipment that cannot tolerate it.
Floating dispensers
A floating dispenser is a perforated canister that drifts on the surface. Pool water washes in through the openings and slowly erodes the tablets. Floaters are cheap and need no plumbing, which makes them common in small residential pools.
- There is little or no control over the dissolution rate beyond adjusting the number of open vents.
- They tend to drift into corners or rest against steps, where locally strong solution can bleach vinyl liners and painted surfaces.
- They should be removed while people are swimming, especially where children may pick them up.
Skimmer baskets
Placing tablets in the skimmer basket is convenient, but every bit of the concentrated, acidic solution then passes straight through the pump, filter and any heater. When the pump stops, the water standing in the skimmer and pipework becomes very strong. Many equipment makers advise against this practice for that reason, and it is generally a poor choice where metal heat exchangers or heat pumps are installed downstream.
Erosion chlorinators
Purpose-built erosion feeders, also called tablet chlorinators, are plumbed into the circulation system, either in-line in the return pipe or off-line on a bypass. A valve or flow adjuster sets how much water passes through the tablet chamber, which gives the operator a real control on chlorine output. Larger units can be fitted with solenoids and linked to an automatic controller that opens the feeder when the measured chlorine falls.
| Device | Output control | Typical tablet | Main risk |
|---|---|---|---|
| Floating dispenser | Very limited | 20 g or 200 g | Surface bleaching, uneven residual |
| Skimmer basket | None; follows pump running | 200 g | Acidic solution through pump and heater |
| In-line or off-line erosion feeder | Flow valve, optionally automatic | 200 g, sometimes 20 g | Gas build-up when flow stops |
Installation and safety points for erosion feeders
- Place the feeder downstream of heaters and heat pumps, usually with a check valve so strong solution cannot drift back into them when the pump stops.
- Expect gas in the chamber after a shutdown. With no flow, chlorine-containing gases collect above the tablets. Open the lid slowly in a ventilated space, keeping your face away, and follow the feeder maker's instructions.
- Dedicate the feeder to one product. A feeder built for TCCA must never be loaded with calcium hypochlorite or any other chlorine product, and old tablet residue must not be mixed with a different chemical. Mixing chlorine products can cause fire, explosion or toxic gas release.
- Watch for bridging at low flow. At very low flows the tablet surface can erode unevenly and leave a crust that holds tablets above the water, so output drops even though the chamber looks full.
- Use the tablet size the feeder is designed for. Tablet diameter and density affect how they stack and erode.
The feeder, not the tablet, decides whether TCCA delivers a steady residual. Size it for the pool's chlorine demand and keep it for TCCA only.
Feeding tablets and pool balance
Whatever the device, continuous TCCA use lowers pH and alkalinity and adds cyanuric acid to the water, roughly 0.6 mg/L for every 1 mg/L of chlorine supplied. Operators therefore test pH, alkalinity and stabiliser regularly and adjust with separate products added separately, never through the tablet feeder.
What to specify when buying
Tell your supplier which feeder you use and the tablet size and weight it accepts, so the offered tablets match. Ask for the available chlorine content on the certificate of analysis, tablet weight tolerance, packing type and the safety data sheet. Nuroil supplies TCCA tablets on request with a certificate of analysis on every delivery; you can send feeder and quantity details through our quote request form.