Oxidised bitumen 85/25, 90/15, 95/25 and 115/15 specifications compared

Typical specification ranges, test methods and uses for oxidised bitumen grades 85/25, 90/15, 95/25 and 115/15, side by side.

Written by the Nuroil trade desk, Sharjah

Pencil sketch of oxidised bitumen production
On this page · 5 sections
  1. 01How the grades are defined
  2. 02Typical specification ranges
  3. 03How the grades differ in practice
  4. 04Heating and handling data
  5. 05Comparing offers and placing an order

Four oxidised bitumen grades account for much of the international trade in blown bitumen: 85/25, 90/15, 95/25 and 115/15. This guide sets out their typical specification ranges, the tests behind them and where each grade is commonly used, so that buyers can compare offers on a like-for-like basis.

How the grades are defined

Each grade is named by its softening point in °C followed by its penetration at 25°C in tenths of a millimetre. The European framework standard BS EN 13304 grades oxidised bitumen by these two properties in steps of five, and the grade name normally gives the midpoint of each acceptance range. Many national standards and producer specifications follow the same pattern, though the exact limits and the full list of properties can differ.

Typical specification ranges

PropertyTest method85/2590/1595/25115/15
Softening point (ring and ball), °CEN 1427 / ASTM D3680 to 9085 to 9590 to 100110 to 120
Penetration at 25°C, dmmEN 1426 / ASTM D520 to 3010 to 2020 to 3010 to 20
Solubility, % minEN 12592 / ASTM D2042Typically 99
Loss on heating, % maxEN 13303 / ASTM D6Typically 0.2 to 0.5, depending on specification
Flash point, °C minCleveland open cupTypically 225 to 250, depending on specification

The ranges shown follow the midpoint convention and agree with published limits for 85/25 and 90/15 in the Indian industrial bitumen standard (which also sets solubility of at least 99%, loss on heating of at most 0.2% and a flash point of at least 225°C) and with a producer's data sheet for 95/25 (solubility at least 99%, loss on heating at most 0.5%, flash point at least 250°C). Some specifications add ductility, specific gravity or other tests. The specification agreed in the contract is what counts.

How the grades differ in practice

  • 85/25 has the lowest softening point of the four and a moderate penetration. It is relatively flexible and is widely used in waterproofing, bonding and as a base for compounds.
  • 90/15 resists heat slightly better than 85/25 but is markedly harder. It is used where firmness matters more than flexibility, for example in some coatings, joint fillers and sealing compounds.
  • 95/25 keeps the moderate penetration of 85/25 while lifting the softening point by about ten degrees. Producers describe it as an industrial grade that is solid at ambient temperatures and gives good adhesion and waterproofing when applied hot, making it a common choice for hot-applied roofing and waterproofing in warm climates.
  • 115/15 is the hardest and most heat resistant. It is considered where high service or storage temperatures are expected, such as some pipe coatings and industrial compounds, but it is the least tolerant of cold and movement.
Two grades with the same penetration can behave very differently on a hot roof; two with the same softening point can behave very differently in the cold.

Heating and handling data

Oxidised grades must be melted for use, so the supplier's handling data matters as much as the specification. As an example, one producer's data for 95/25 gives a guide minimum pumping temperature of about 170°C, a pouring temperature of about 205 to 215°C, and a maximum safe handling and storage temperature of 230°C. Harder, higher softening point grades generally need higher working temperatures. Always use the figures on the product's own data sheet and SDS rather than general values.

Comparing offers and placing an order

When comparing quotations, check that each supplier is offering the same specification ranges, not just the same grade name, and that all the properties you need appear on the certificate of analysis with their test methods. Your enquiry should state:

  • grade and specification (standard or agreed data sheet);
  • end use and climate at the point of use;
  • packing, such as bags, drums or cartons, and palletising;
  • quantity, destination port and Incoterm;
  • documents needed, such as CoA, CoO, SDS and third-party inspection.

Nuroil supplies oxidised bitumen in these grades from established producers, with a CoA for every delivery and other documents on request. Send your specification through the quote form.

PRODUCTS IN THIS GUIDE
KEEP READING

More from the Knowledge Centre.