Technical document

· PDF

Tell us who you are and the document downloads straight away. We use these details only to follow up on your requirement.

Samples & documents

What can we send you?

Tick what you need
Request a quote
Expert article3 min read6 sections

Knowledge centre · Fuel oil & engines

Changing over to MGO before entering an emission control area

Why ships switch from residual fuel to marine gasoil before an emission control area, and how to manage temperature, viscosity and timing safely.

Written by the Nuroil trade desk, Sharjah

Pencil sketch of ship-to-ship fuel oil transfer
On this page · 6 sections
  1. 01Where the 0.10% limit applies
  2. 02The temperature problem
  3. 03The viscosity problem
  4. 04Other risks during changeover
  5. 05A typical changeover sequence
  6. 06Buying MGO for ECA operation

Inside an emission control area (ECA), ships must burn fuel with no more than 0.10% sulphur unless they use an approved equivalent such as a scrubber. For most ships that means changing over from residual fuel, either VLSFO or HSFO, to marine gasoil (MGO) before crossing the boundary. The changeover looks simple on paper but has caused loss of propulsion incidents when done badly. This article explains what happens to the fuel system and how operators manage it.

Where the 0.10% limit applies

MARPOL Annex VI designates sulphur ECAs in the Baltic Sea, the North Sea, the North American area and the United States Caribbean Sea, and further areas, including the Mediterranean Sea, have been added since. Ships are expected to complete the changeover before entering and to record the time, position and tank contents in the logbook. Some ports also require low sulphur fuel at berth.

The temperature problem

Residual fuel must be heated so that its viscosity at the engine inlet falls to the range the injection equipment needs, typically around 10 to 20 cSt. That usually means fuel temperatures of roughly 120°C to 140°C. MGO, in contrast, is injected at close to ambient temperature, often 30°C to 40°C. A changeover therefore involves cooling the fuel system by around 100°C.

If that drop happens too quickly, the precision-fitted plungers and barrels of the fuel pumps can contract at different rates and seize. Engine makers commonly advise a maximum rate of change of about 2°C per minute at the engine inlet, which means a changeover typically takes an hour or more.

The viscosity problem

MGO is thin. Under ISO 8217, a DMA distillate must have a viscosity of at least 2.0 cSt at 40°C, but once it warms up in a hot fuel system its viscosity can fall below what the pumps need to seal and lubricate properly. Many engine makers set a minimum of around 2 cSt at the engine inlet, with figures varying between about 1.8 and 3 cSt depending on the engine. Too low a viscosity causes internal leakage in the pumps, which shows up as poor starting, difficulty running astern and unstable low-load operation. Some ships fit a fuel cooler or chiller so that MGO stays cool enough.

Other risks during changeover

  • Incompatibility. As MGO mixes with residual fuel in the system, the paraffinic distillate can destabilise asphaltenes in the residual fuel, producing sludge that blocks filters.
  • Leaks. Thin distillate finds its way through seals and fittings that were tight on heavy fuel.
  • Boiler flame stability. Burners set up for heavy fuel may need different settings on MGO.
  • Cylinder lubrication. Two-stroke engines may need a cylinder oil with lower base number for prolonged running on low sulphur fuel.

A typical changeover sequence

  1. Plan the start time from a changeover calculator so that the system is fully on compliant fuel before the ECA boundary.
  2. Reduce engine load to a steady level recommended by the engine maker.
  3. Turn off steam tracing on fuel lines and lower the fuel heater set point gradually.
  4. Open the MGO supply so that it blends into the system, watching the inlet temperature rate of change.
  5. Monitor viscosity, temperature, filter differential pressure and pump behaviour throughout.
  6. Bring in the fuel cooler if viscosity approaches the engine's lower limit.
  7. Record the completion time, position and remaining fuel quantities in the log.

The reverse changeover on leaving the ECA also needs care, because heating must be increased gradually.

Plan the changeover around the slower of two limits: how fast the fuel system may cool, and how thin the fuel may become at the engine inlet.

Buying MGO for ECA operation

When ordering MGO for ECA use, specify the ISO 8217 distillate grade (usually DMA or DMZ), the edition of the standard, a maximum sulphur of 0.10%, and a minimum viscosity suited to your engines. Ask for the viscosity, flash point and cold flow properties to be shown on the quality certificate. Ships trading in cold regions should also specify cloud point or cold filter plugging point. Nuroil supplies marine gasoil on request; see the bunker and marine fuel page.

PRODUCTS IN THIS ARTICLE
KEEP READING

More from the Knowledge Centre.

STILL HAVE A QUESTION?

Ask the people who trade it every day.

Our trade managers answer technical and commercial questions about grades, specifications, packing and shipping.