ASTM D3381 is the American standard for viscosity-graded paving bitumen. Its AC grades (AC-2.5, AC-5, AC-10, AC-20, AC-30 and AC-40) still appear in tenders in many regions. This guide summarises the grades and the properties the standard controls, so that buyers can read an AC specification with confidence.
How the standard is organised
D3381 grades binder by viscosity at 60°C (140°F). Unusually, it offers more than one table of requirements. The purchaser chooses which table applies, and if none is named, Table 1 is used by default. This means two AC-20 offers can be certified against different sets of limits, so the table matters as much as the grade. The standard also contains AR grades, which are based on aged residue rather than the binder as supplied.
Recent editions have been retitled to refer to asphalt binder and give values in SI units (pascal seconds and mm²/s) alongside poise and centistokes.
Main requirements of Table 1
The following summarises the commonly cited Table 1 values from the 2009 edition. Check the current edition before using them in a contract.
| Grade | Viscosity at 60°C, poise | Viscosity at 135°C, cSt min | Penetration at 25°C, min | Flash point, °C min |
|---|---|---|---|---|
| AC-2.5 | 250 ± 50 | 80 | 200 | 163 |
| AC-5 | 500 ± 100 | 110 | 120 | 177 |
| AC-10 | 1000 ± 200 | 150 | 70 | 219 |
| AC-20 | 2000 ± 400 | 210 | 40 | 232 |
| AC-30 | 3000 ± 600 | 250 | 30 | 232 |
| AC-40 | 4000 ± 800 | 300 | 20 | 232 |
Flash points in the standard are set in °F (325, 350, 425 and 450°F); the Celsius figures are conversions. In SI units the 60°C bands become 25 ± 5 Pa·s for AC-2.5 up to 400 ± 80 Pa·s for AC-40.
Ageing and other requirements
Each grade also has limits on the residue after a thin film oven test, which simulates hardening during mixing:
- Residue viscosity at 60°C, maximum. It rises from 1250 poise for AC-2.5 to 20,000 poise for AC-40, roughly five times the nominal grade viscosity.
- Residue ductility at 25°C, minimum. 100 cm for the softest grades, falling to 10 cm for AC-40.
- Solubility in trichloroethylene. A minimum purity requirement.
Reading the grade names
The number after AC is the nominal 60°C viscosity in hundreds of poise. The ±20% tolerance gives bands such as 1600–2400 poise for AC-20 and 2400–3600 poise for AC-30, while AC-30 and AC-40 overlap between 3200 and 3600 poise. The AC-10, AC-20, AC-30 and AC-40 bands are the same as the VG-10 to VG-40 bands of IS 73, although the other limits in the two standards differ.
| AC grade | Typical role |
|---|---|
| AC-2.5, AC-5 | Soft grades for cold climates, surface treatments and emulsion base |
| AC-10, AC-20 | General paving in cool to moderate climates; AC-20 widely used |
| AC-30, AC-40 | Hot climates and heavy, slow traffic |
As with any grade system, actual values on the certificate are more informative than the label. Within one AC grade a lot can sit anywhere in a band 40% wide, which is enough to change plant temperatures and compaction behaviour. For long projects, ask for consistent supply from one source and compare the 60°C and 135°C results of successive lots.
Limits of AC grading
Two binders of the same AC grade can show widely different viscosities after ageing, so they may perform differently once laid. The residue limits narrow this but do not remove it, which is why AR grading and later performance grading were developed.
An AC grade without its table number is an incomplete specification.
Specifying AC grades
State the grade, ASTM D3381 with its edition and table, the quantity and packing. Ask for a CoA reporting both viscosities, penetration, flash point, solubility and the thin film oven residue results. Nuroil can offer viscosity grade bitumen against AC and VG specifications; send your tender requirements through request a quote.