Technical document

· PDF

Tell us who you are and the document downloads straight away. We use these details only to follow up on your requirement.

Samples & documents

What can we send you?

Tick what you need
Request a quote
Guide3 min read6 sections

Knowledge centre · Bitumen

AC-2.5 to AC-40: a reference to ASTM D3381 viscosity grades

The ASTM D3381 AC grades set out one by one: 60°C and 135°C viscosity, penetration, flash point and ageing limits, plus notes on its tables.

Written by the Nuroil trade desk, Sharjah

Pencil sketch of a glass capillary viscometer in a 60 °C water bath
On this page · 6 sections
  1. 01How the standard is organised
  2. 02Main requirements of Table 1
  3. 03Ageing and other requirements
  4. 04Reading the grade names
  5. 05Limits of AC grading
  6. 06Specifying AC grades

ASTM D3381 is the American standard for viscosity-graded paving bitumen. Its AC grades (AC-2.5, AC-5, AC-10, AC-20, AC-30 and AC-40) still appear in tenders in many regions. This guide summarises the grades and the properties the standard controls, so that buyers can read an AC specification with confidence.

How the standard is organised

D3381 grades binder by viscosity at 60°C (140°F). Unusually, it offers more than one table of requirements. The purchaser chooses which table applies, and if none is named, Table 1 is used by default. This means two AC-20 offers can be certified against different sets of limits, so the table matters as much as the grade. The standard also contains AR grades, which are based on aged residue rather than the binder as supplied.

Recent editions have been retitled to refer to asphalt binder and give values in SI units (pascal seconds and mm²/s) alongside poise and centistokes.

Main requirements of Table 1

The following summarises the commonly cited Table 1 values from the 2009 edition. Check the current edition before using them in a contract.

GradeViscosity at 60°C, poiseViscosity at 135°C, cSt minPenetration at 25°C, minFlash point, °C min
AC-2.5250 ± 5080200163
AC-5500 ± 100110120177
AC-101000 ± 20015070219
AC-202000 ± 40021040232
AC-303000 ± 60025030232
AC-404000 ± 80030020232

Flash points in the standard are set in °F (325, 350, 425 and 450°F); the Celsius figures are conversions. In SI units the 60°C bands become 25 ± 5 Pa·s for AC-2.5 up to 400 ± 80 Pa·s for AC-40.

Ageing and other requirements

Each grade also has limits on the residue after a thin film oven test, which simulates hardening during mixing:

  • Residue viscosity at 60°C, maximum. It rises from 1250 poise for AC-2.5 to 20,000 poise for AC-40, roughly five times the nominal grade viscosity.
  • Residue ductility at 25°C, minimum. 100 cm for the softest grades, falling to 10 cm for AC-40.
  • Solubility in trichloroethylene. A minimum purity requirement.

Reading the grade names

The number after AC is the nominal 60°C viscosity in hundreds of poise. The ±20% tolerance gives bands such as 1600–2400 poise for AC-20 and 2400–3600 poise for AC-30, while AC-30 and AC-40 overlap between 3200 and 3600 poise. The AC-10, AC-20, AC-30 and AC-40 bands are the same as the VG-10 to VG-40 bands of IS 73, although the other limits in the two standards differ.

AC gradeTypical role
AC-2.5, AC-5Soft grades for cold climates, surface treatments and emulsion base
AC-10, AC-20General paving in cool to moderate climates; AC-20 widely used
AC-30, AC-40Hot climates and heavy, slow traffic

As with any grade system, actual values on the certificate are more informative than the label. Within one AC grade a lot can sit anywhere in a band 40% wide, which is enough to change plant temperatures and compaction behaviour. For long projects, ask for consistent supply from one source and compare the 60°C and 135°C results of successive lots.

Limits of AC grading

Two binders of the same AC grade can show widely different viscosities after ageing, so they may perform differently once laid. The residue limits narrow this but do not remove it, which is why AR grading and later performance grading were developed.

An AC grade without its table number is an incomplete specification.

Specifying AC grades

State the grade, ASTM D3381 with its edition and table, the quantity and packing. Ask for a CoA reporting both viscosities, penetration, flash point, solubility and the thin film oven residue results. Nuroil can offer viscosity grade bitumen against AC and VG specifications; send your tender requirements through request a quote.