AC and AR grades: the two ways of viscosity grading bitumen

What AC-10, AC-20 and AC-30 mean, how AR grades such as AR-4000 differ, and how both relate to the VG grades used in many tenders.

Written by the Nuroil trade desk, Sharjah

Pencil sketch of a glass capillary viscometer in a 60 °C water bath
On this page · 6 sections
  1. 01Why viscosity grading appeared
  2. 02AC grades: graded as supplied
  3. 03AR grades: graded after ageing
  4. 04How the systems compare
  5. 05What came after
  6. 06Specifying AC, AR or VG

Tender documents for paving bitumen may ask for AC-20, AR-4000 or VG-30. All three are viscosity grades, but they are not the same thing. AC and AR are the two original viscosity grading approaches developed in the United States, and the VG grades used in many other markets follow the AC idea. This article explains the logic of each.

Why viscosity grading appeared

From the early 1900s paving binders were classified by penetration, an empirical needle test at 25°C. In the early 1960s an alternative was introduced that graded binder by viscosity, a fundamental property, measured at temperatures linked to service and construction: 60°C for a hot pavement and 135°C for mixing. Penetration at 25°C was kept as a supporting test.

AC grades: graded as supplied

AC stands for asphalt cement. An AC grade is set by the viscosity of the binder as delivered, measured at 60°C, with the number giving the nominal viscosity in hundreds of poise. AC-20, for example, has a nominal viscosity of 2000 poise at 60°C. ASTM D3381 and AASHTO M 226 define six AC grades from AC-2.5 to AC-40, each with a tolerance of about ±20% around the nominal value.

The weakness of AC grading is that it says nothing directly about how much the binder hardens during mixing. Two AC-20 binders can show quite different viscosities after a thin film oven test and so perform differently once in the road.

AR grades: graded after ageing

AR stands for aged residue. Here the binder is first aged in the rolling thin film oven, which simulates hardening in the hot-mix plant, and the grade is assigned from the 60°C viscosity of that residue. ASTM D3381 lists AR-1000, AR-2000, AR-4000, AR-8000 and AR-16000, where the number is the nominal aged viscosity in poise. AASHTO M 226 uses the same grades with shortened names (AR-10 to AR-160).

Because AR grading measures the binder in the condition it will be in when the road opens, it is a closer reflection of in-service behaviour. It was used particularly in the western United States. Typical US paving grades under these systems were AC-10, AC-20, AC-30, AR-4000 and AR-8000.

How the systems compare

PointAC gradesAR gradesVG grades (IS 73)
Binder gradedAs suppliedAfter RTFOT ageingAs supplied
Grading temperature60°C60°C60°C
Grade number meansNominal viscosity ÷ 100 (poise)Nominal aged viscosity (poise)Viscosity band in hundreds of poise, roughly
Ageing controlLimit on residue viscosity and ductilityBuilt into the gradeViscosity ratio max 4 after RTFOT
Example gradesAC-10, AC-20, AC-30, AC-40AR-4000, AR-8000VG-10, VG-20, VG-30, VG-40

VG grades are graded on the binder as supplied, like AC grades, and the numbers follow a similar scale: VG-30 has a 60°C viscosity of 2400–3600 poise, the same band as AC-30. IS 73 controls ageing separately, capping the ratio of aged to original viscosity at 4. VG and AC grades of the same number are close relatives, not identical products, and each carries its own limits on penetration, flash point and residue properties.

AC tells you the binder before the plant; AR tells you the binder after it. Both use the same 60°C viscosity yardstick.

What came after

Both AC and AR grading are still used, but many highway agencies later adopted performance grading, which tests binder across the range of temperatures a specific pavement will see and includes long-term ageing. Even so, viscosity grades remain common in tenders because the tests are well understood, widely available and less costly to run. When a project allows any of these systems, the governing specification should say which one controls acceptance.

Specifying AC, AR or VG

Write the grade exactly as the project specification does, with the standard and table if the standard offers several, as ASTM D3381 does. Ask for both viscosities and the ageing results on the certificate of analysis. Nuroil supplies viscosity grade bitumen including AC and VG grades; contact us with your specification to confirm which grades can be offered.