Technical document

· PDF

Tell us who you are and the document downloads straight away. We use these details only to follow up on your requirement.

Samples & documents

What can we send you?

Tick what you need
Request a quote
Expert article3 min read5 sections

Knowledge centre · Lubricants & base oil

Haze, cloud point and cold weather in SN500 base oil

Why heavy Group I grades such as SN500 can turn hazy in cold tanks, how to tell wax haze from water, and what to check before rejecting a lot.

Written by the Nuroil trade desk, Sharjah

Pencil sketch of Group I base oil with refinery and drums
On this page · 5 sections
  1. 01Why heavy neutrals are prone to haze
  2. 02Cloud point and pour point: what they tell you
  3. 03Wax haze or water haze?
  4. 04Practical steps in storage
  5. 05Agreeing the test in advance

A receiving tank of SN500 that looked bright at the load port can look cloudy on a cold morning at destination. This is one of the most common quality queries on heavy Group I base oil. Often the product is still within specification, but sometimes the haze points to water or contamination. Knowing the difference saves time and avoids unnecessary claims.

Why heavy neutrals are prone to haze

Solvent dewaxing removes most of the waxy paraffins by chilling and filtering, but it is harder to do completely on heavy cuts. Heavier streams contain wax-like molecules and other haze precursors that are less easily separated than the simple paraffins in light distillates. As a result, SN500 and bright stock generally have higher pour points and cloud points than SN150 from the same refinery.

Patent literature on base oil processing also notes that heavy stocks can form a faint haze at temperatures above the measured cloud point, especially when the oil stands at a low temperature for several hours. The haze typically clears when the oil is warmed slightly.

Cloud point and pour point: what they tell you

Cloud point is the temperature at which wax crystals first appear as a haze when the oil is cooled under standard conditions. ASTM D2500 is the traditional manual method; automated methods such as ASTM D5771 and D5773 give comparable results faster. Pour point, measured by ASTM D97 or an automated equivalent, is the lowest temperature at which the oil still flows. The cloud point is always at or above the pour point, and the gap tends to be wider in highly paraffinic oils.

Typical SN500 specifications set pour point at a maximum of about -6 to -9 °C. Cloud point is not always on the specification sheet, so ask for it if your tanks sit in a cold climate.

Wax haze or water haze?

ObservationWax haze is likelyWater or contamination is likely
Warm a sample to about 40 to 50 °CHaze clears and stays clear while warmHaze stays, or droplets form
Sample left to settleNo free water layerFree water or sediment at the bottom
Crackle test on a hot plateNo crackleCrackling or spitting
Karl Fischer water contentWithin normal rangeElevated
Ambient historyCold night, unheated tankRain, condensation, open hatch, wet drums

The hot plate test is only a screen. A laboratory water test by Karl Fischer titration and a visual check of a properly drawn sample are the reliable confirmation.

Practical steps in storage

  • Keep heavy-grade tanks above the cloud point where the climate allows, using gentle heating rather than local hot spots.
  • Sample from the correct level after the product has stood at a steady temperature; a sample drawn cold from a tank bottom may not represent the batch.
  • Store drums on their side or under cover so rainwater does not collect on the heads and get drawn in as the drum breathes.
  • When a blend containing SN500 shows haze, check whether the base oil, the additive package or an interaction is responsible before changing supplier.
Wax haze that clears on gentle warming is usually a property of heavy Group I grades, not a defect. Haze that stays when warm needs a water and contamination check.

Agreeing the test in advance

Disputes are easier to settle when the contract states the appearance test and its temperature, for example clear and bright at a stated temperature, and the pour point method. If your market has cold winters, add a cloud point limit to the enquiry. Ask for a certificate of analysis showing appearance, pour point and water content for the lot, and keep sealed retained samples from loading. Nuroil provides a CoA with each SN500 delivery and can arrange independent inspection at loading on request; contact us to discuss the limits your application needs, or see the Group I base oil page.

PRODUCTS IN THIS ARTICLE
KEEP READING

More from the knowledge centre.

STILL HAVE A QUESTION?

Ask the people who trade it every day.

Our trade managers answer technical and commercial questions about grades, specifications, packing and shipping.

LET’S TALK ABOUT YOUR REQUIREMENTS

Your next shipment starts here.

Request a quote