Few finished lubricants use a single base oil grade. Industrial oils from ISO VG 32 to VG 460 are usually built by combining SN150, SN500 and bright stock in the right proportions, then adjusting for the additive package. This guide explains how blenders estimate those ratios and what to watch for when a new lot of base oil arrives.
The building blocks
Each Group I grade covers a slice of the viscosity scale. The figures below are approximate and vary between producers, which is exactly why blend ratios need checking against the actual lots.
| Grade | Approximate viscosity at 40 °C | Approximate viscosity at 100 °C | Nearest ISO VG |
|---|---|---|---|
| SN150 | About 30 mm²/s | About 5 mm²/s | VG 32 |
| SN500 | About 95 to 110 mm²/s | About 11 mm²/s | VG 100 |
| Bright stock (150 BS) | Several hundred mm²/s | About 30 mm²/s | Above VG 460 |
ISO VG grades are defined at 40 °C with a band of plus or minus 10 per cent around the midpoint, so VG 68 covers 61.2 to 74.8 mm²/s and VG 220 covers 198 to 242 mm²/s.
Why simple averaging does not work
Viscosity does not blend linearly. Mixing equal parts of a 30 mm²/s oil and a 100 mm²/s oil does not give 65 mm²/s; the result is noticeably lower, because the thinner component has a disproportionate effect. Blenders therefore use logarithmic relationships, the same family of equations behind the viscosity-temperature charts of ASTM D341.
ASTM D7152 sets out a standard practice for this calculation. It describes two approaches. The Wright method uses each component's viscosity at two temperatures and is generally the more accurate. The simpler ASTM method needs viscosity at one temperature only. Both have inverse forms that solve for the fraction of each component needed to reach a target. The standard notes that for base stock blends, using mass or volume fractions makes little practical difference, and that it does not apply well to viscosity index improvers or additive packages.
A practical blending sequence
- Take the measured viscosities from the certificates of analysis of the lots in your tanks, not the grade's nominal values.
- Decide which pair of grades brackets the target: SN150 with SN500 for VG 46 to VG 100, SN500 with bright stock for VG 150 to VG 460.
- Estimate the ratio with a D7152-type calculation, allowing for the viscosity the additive package will add or, for some packages, take away.
- Make a laboratory blend and measure viscosity at 40 °C. Adjust the ratio and record the correction factor for that additive and base oil pairing.
- Scale up, and check the first production batch before release.
Other properties that change with the ratio
- Viscosity index. Blends usually land between the components, but bright stock-rich blends can sit lower than expected.
- Flash point. The light component dominates. A small proportion of a low-flash SN150 can pull the blend's flash point down.
- Pour point. Heavy components often set the pour point of the blend, so a VG 220 gear oil may need a pour point depressant even if the SN150 alone would not.
- Colour and carbon residue. Rise with the bright stock share.
- Solvency. Remains good across Group I blends, which keeps most industrial additive packages in solution.
Blend from measured lot viscosities, use a logarithmic method such as ASTM D7152, and confirm with a laboratory batch before scaling up.
Supply implications
Because each new lot can shift the ratio slightly, consistent supply of all three grades from the same source simplifies production. When you enquire, give the viscosity windows you work to for each grade rather than grade names alone, and ask for certificates of analysis that report viscosity at both 40 and 100 °C, which lets you use the more accurate two-temperature method. Nuroil can quote SN150, SN500 and bright stock together with a CoA for every lot; request a quote or visit the Group I base oil page.